12
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Kozy Power Vent #KPV
Figure 3.11, Tape Measure Wire
Figure 3.12, Vacuum Switch
Figure 3.13, Wires Connected
NOTE: Make sure there is no more than 6 inches of wire extending
through the back cap cover. See Figure 3.11.
5. Attach the red and brown wires to the vacuum switch as shown
in Figure 3.12.
6. Attach the white and black wires from the #KPV harness to the
black wires coming from the blower. Attach the green wire from
the #KPV harness to the green/yellow wire coming from the fab.
7. NOTE: After all wires are connected, the wire should look like the
picture in Figure 3.13.
8. Proceed to Section 3.5.1 Finishing Materials on page 13.