3.3 Hearth and Mantel Clearances
The following drawings show the hearth and mantel clearances
allowed for the CLW-50 and BHM-44 with no surround or optional
surrounds installed (if applicable). Follow the drawings for the
minimum distance needed between the hearth and mantel when
installing an optional surround to allow for proper servicing
clearances.
3.3.1 CLW-50 Finishing Guidelines
for Optional Surrounds
•
Figure 3.7 shows where to end finishing materials, when
measuring from the finishing edge, to allow installation of any
optional surround. Most finishing material will not fit behind the
optional surround(s) when it is installed.
•
Measurement 'A' shows the space to leave on each side.
•
Measurement 'B' shows the space to leave on the top and the
bottom.
Figure 3.7, Finishing Guidelines for Optional Surrounds
Surround
A
B
CW50-RS
3/4" (19mm)
1-1/2" (38mm)
CW50-RS4
2-5/8" (66mm)
2-5/8" (66mm)
CW50-GS
6" (152mm)
2-1/2" (64mm)
CW50-FS
3-1/8" (79mm)
3-1/8" (79mm)
B
A
Finishing Trim Edge
Surround Edge
Steel
Framing
Non-Combustible Zone
16
¾
”
(425mm)
26
½
”
(673mm)
9
¾
”
(248mm)
12” (305mm)
9” (229mm)
6” (152mm)
12” (305mm)
9” (229mm)
6” (152mm)
Combustible wall finish
may be installed over cement
board and butt up to the finshing
edge around the opening
Each square represents
1” (25mm)
of mantel projection
Finishing Edge
Fireplace Enclosure Floor
Finishing Edge
½
” (13mm) clearance
around pipe
No Surround
Non-combustible
material
CLW-50
Figure 3.8, Hearth and Mantel Clearances for No Surround