24
FRAMING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CLW-ST R.1 February 2021
Remove (4) cover plates for a Komfort Zone Kit or
vented cavity options for the front or the top vent cavity
Figure 3.14, Cover Plate Removal
3.9 Vented Cavity and Komfort
Zone Kit Installation
3.9.1 Komfort Zone Kit and Vented
Cavity Preparation Overview
The Komfort Zone Kit and Vented Cavity design options have specific
framing requirements, mantel requirements, and exterior trim
dimensions. The appliance convection baffles and outer shell cover
plates must be removed for heat distribution required by cavity
framing designs.
•
Full enclosure framing requirements in Section 3.5.2 Rough
Framing on page 18 will apply to the vented cavity and KZK
installation. Shelf enclosure framing is not allowed for these
design options.
•
All minimum required dimensions must be maintained after all
finishing materials are installed.
1. Remove the (4) top cover plates that correspond to the vented
cavity options for the single opening vented cavity, the dual
opening vented cavity, or the top vented cavity. See Figure 3.14.
If planning to install a Komfort Zone kit, these (4) cover plates
will also have to be removed. See the
#KZK-054 or #KZK-1510A
manual for further fireplace preparation.
2. Remove the (6) convection baffles from the appliance. The
baffles are secured by (2) screws each behind the upper edge of
both fireplace openings. See Figure 3.16. Recycle these panels as
they are no longer needed.
Convection airflow with baffles removed
Figure 3.15, Air Flow inside Appliance with Convection Baffles Removed