#BAY-36-L & BW R.8 July 2019
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING
13
3.5 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-offs
0 in
0 mm
From appliance left and right side stand-offs
0 in
0 mm
From appliance back stand-offs
0 in
0 mm
From appliance corners
1/4 in
6 mm
From appliance front
36 in
914 mm
From appliance top to ceiling
30 in
762 mm
Appliance sides to adjacent sidewall
3/4 in
19 mm
Top of appliance to 3/4 in (19 mm) trim
4-1/2 in
108 mm
Mantel 6 in (152 mm) deep from appliance top
8 in
203 mm
Figure 3.2, Typical Installation Options