Under power on condition,the indicator light of power will be twinkling,and 

then press it will be turned on.The multi-color,the carbon fiber  heater,and the 

far infrared heater will be turn on at the same time.The display show 45

 

temperature for 5 seconds, if there's no any operation, 5 seconds later it will 

renew to the temperature of nature.The setted time when it turn on is 30 

minutes, at the same time,the indicator light will turn on.Press again, it will 

turn off and turn off all of the function and display

Press infrared sauna group A/B to start infrared sauna fuction.

Press infrared sauna key the first time with 100% power,

Second time power90%,

Third time power80%,

Fourth time power70%,

While fifth time to close it.

Under turn on condition,press time+ / time- ,the time will be downwards or 

upwards 1 minute,press the key about 1 second,it will be automatically quickly 

adjusting.The scale of time adjusting is 01-99 minutes.                                       

Under turn on condition,press temp/temperature-,the time will be 

downwards or upwards 1

,press the key about 1 second,it will be quickly 

adjusting  automatically.The scale of temperature adjusting is 35

60

.When 

the temperature inside reach to the setted temperature,the system will adjust 

the power into 70%.When temperature inside is 2

 lower than the setted 

temperature,the system will adjust the power into 100% power.

Press color light key to adjust the color lamp by hand.It works circularly from 

white/green/yellow/blue/red/turn off.Top lamp is  controled by the key 

within15minutes after shut down the control panel. The control system will 

turn off multh-color lamp function automatically aftor shuting the system for is 

minutes,Once turn on power,white is acquiescence.

1.Turn on/Turn off

2. Infrared sauna

3.Time/Temperature setting

4.Multi-color top lamp

Summary of Contents for 05-k1

Page 1: ...PRODUCT MANUAL Model 05 k1...

Page 2: ......

Page 3: ...ist KYO718AA KYO715CA KYO713AA Parameter parts drawing Installation drawing KYO718AA KYO715CA KYO713AA Warning Usage Notice Reminder Maintainance Trouble Shooting Safety Instruction KYO713AA KY0715CA...

Page 4: ...list 5 60 10pcs 4 30 6pcs 4 25 4pcs 4 18 4pcs 4 12 18pcs Heater underlay 4pcs 10 3pcs Wire fixer 7pcs 8 Wire fixer Pulley 2PCS Pulley 2PCS 5 70 4pcs 4 25 4pcs Decorated washer 6pcs Decorated screw ca...

Page 5: ...3 0 KYO718AA...

Page 6: ...04 KYO715CA...

Page 7: ...AC220 240V Rated Power 1820W Rated Current 8A Rated frequency 50 60HZ Insulated Resistance 20M Class I Back Side board heater AC220 240V 350W Leg heater AC220 240V 300W Front heater AC220 240V 150W Fa...

Page 8: ...2 14 Glass door 15 16 1 A Fan 1 1 B 1 C D Parts drawing Parts drawing Model Size 1000 958 2000mm No Parts name Qty No Parts name Qty Right seat rack Left seat rack back board Backrest Front heater cor...

Page 9: ...tion drawing Step Material Qty Size Step 1 Step 2 Attention The side board bottom slot must be aimed at the floor batten left side board floor batten lead rail batten side board 90 floor batten 1 Scre...

Page 10: ...08 Installation drawing Step 3 Step Material Qty Size Step 4 4 4 Screw ST5 70mm 4 Screw ST4 18mm 4 Screw ST4 25mm 4 3...

Page 11: ...9 0 Installation drawing Step 5 Step 6 6 6 Screw ST5 60mm Plastic seal LR007 6 Step Material Qty Screw Size ST4 30mm Decorated screw cap 5 5 5 Decorated washer 6 6 6...

Page 12: ...8 4 10 Installation drawing Step 7 Step Material Qty Size Screw ST5 60mm Step 8...

Page 13: ...tallation drawing Step 8 Step 9 Material Qty Size Screw Plastic seal LR001 3 4 Plastic seal LR001 3 4 Plastic seal BF002 6 15 5 9 2 540mm Plastic seal 9 2 500mm Plastic seal Plastic seal BF001 06 Hole...

Page 14: ...12 Installation drawing Step 10 Step Material Qty Size 10 up Pulley 4 10 down Pulley 4 Adjust the screw to adjust the height of the glass door...

Page 15: ...3 1 11 Handle 3 1 Installation drawing Step Material Qty Size Step 11...

Page 16: ...r on off A Temperature FM B Temperature indicator light C MP3 D FM tune indicator light E Volume time F Volume adjust indicator light G Time setting indicator light H Infrared sauna group A light I In...

Page 17: ...wards or upwards 1 minute press the key about 1 second it will be automatically quickly adjusting The scale of time adjusting is 01 99 minutes Under turn on condition press temperature temperature the...

Page 18: ...light of frequency will be turn off Press FM again the radio will be turn off The display show OFF world for 10 seconds The scale of frequency is 87 5 108MHZ Adjust the frequency under radio on press...

Page 19: ...Key 06 Key 07 CD MP3 FM 08 Menu 09 Play Pause 10 Power on off Screen A Temp FM B Colour light C Fan D CD E MP3 F Lock G Volume time H Volume setting I FM MP3 setting J Temp setting K Time setting L I...

Page 20: ...the frequency you turn off last time at the same time the frequency will be shown on the display then the MP3 will be shown on the display Press FM key again the radio will be turn off The scale of fr...

Page 21: ...1second it will be automatically quickly adjusting The scale of time adjusting is 5 30 minutes Under turn on condition press temperature temperature the time will be downwards or upwards 1 press the k...

Page 22: ...The power socket switch must be grounded reliably any allident it brings our company is not responsible for it 11 Please take attention to rated voltage and power supply if not match then can t be us...

Page 23: ...ube board Temperature off and 1 2 Connect well the supply cord 3 Replace speaker Adjust volume 1 2 Connect well the supply cord 3 Replace the multicolor lamp Turn on color light 1 2 Connect well the s...

Page 24: ...mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should...

Page 25: ...Power Box Temp de tector Antenna USB IN Ozone 3 Speaker 8 10W DC12V 5W Control Box DC12V 5W CD Control ControIIing Power Box Temp de tector Antenna USB IN Ozone 3 Speaker 8 10W DC12V 5W DC12V 5W Contr...

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: