Safety instructions
1. Read and strictly follow this installation and operating instructions to ensure a
long life and reliable cylinder operation.
2. The manufacturer of this cylinder will not be liable for any damages due to the
failure to follow the installation and operation instructions.
3. The cylinder must not be installed in rooms where the temperature may drop
below 0°C.
4. The cylinder installation and the initial start-up, as well as all electrical and
hydraulic work must be performed by a qualified professional installer- in strict
accordance with assembly and operating instructions.
5. The cylinder is designed for standing vertical installation- screw on three feet.
6. The device must be installed in such a place and in such a way in order not to
flood the room in case of the emergency water leak.
7. Connections to water supply system, central heating system, and solar collec-
tors must be made in accordance with the diagram in this installation instruction.
Failure to follow the installation instruction invalidate the warranty and may cause
cylinder’s damage.
8. Connections to water supply system must be made in accordance with the legally
binding standards.
9. The cylinder is a pressure appliance designed for connection to the water supply
system where the water pressure doesn’t exceed 0,6 MPa. If the water pressure
exceeds 0,6 MPa, the pressure reducing valve before cylinder must be fitted.
10. A small leak from the safety valve through the outlet pipe may occur, it is a normal
operating state of the appliance. The outlet of the pipe has to remain open. Do
not clog it, as a clogged outlet may cause cylinder’s breakdown.
11. Do not use the cylinder if you suspect that the safety valve may be faulty.
12. The tank is equipped with a magnesium anode - an additional protection against
corrosion. The anode is an operating part, therefore, it is exposed to wear.
The condition of the magnesium anode should be controlled every 12
months. The anode must be replaced once every 18 months.
13. Rated temperature of water in the cylinder should not exceed 80°C.