Kospel LUXUS KDH-12 Operating And Installation Instructions Download Page 8

8

This  heater  has  two  safety  de-

vices  that  protect  this  appliance 

from damage or failure:
-  safety temperature limiter WT3, 

that  goes  off  (shuts  off  power 

supply) when the temperature in 

the heating compartment [1] goes 

over 100

0

C. After going the safety 

temperature limiter off, operation 

of the appliance is not possible. 

The safety temperature limiter 

does not work as electric protec-

tion of the heater. 

Fig.10  Construction

 

[1] -  heating box

 

[2] -  differential pressure switch

 

[3] -  WT3 safety temperature lim-

iter

 

[4] -  protection wire terminal

 

[5] -  plugged  hole  for  electric 

wires 

 

[5a] -  hole for electric wires

 

[7] -  back plate

 

[13] -  orifice

 

[15] -  fixing screws

 

[16] -  catches

 

[17] -  inlet pipe - cold water

 

[18] -  outlet pipe - hot water

 

[19] -  flow regulating valve

 

[XP] -  electric terminal

Any  interference  inside  the 

safety temperature limiter may 

cause an irreversible damage to 

the water heater.

In case, the heater forces another 

electric appliance to be off for its high 

power intake, you need to install a 

priority switch. A current relay should 

be  installed  in  a  distribution  board 

into a wire connected to the terminal 

marked "V" at WT3 [3]. While the first 

heating coil is being switched on, the 

current that passes through the coil 

causes the electric relay to work, and  

the extra circuit is opened.

 

10

Construction

Summary of Contents for LUXUS KDH-12

Page 1: ......

Page 2: ...operating instructions carefully to ensure the long life and reli able operation of this appliance The manufacturer may make minor changes in the appliance if necessary They will not be exposed in th...

Page 3: ...osion and chemically inactive copper brass and stainless steel Description Technical data KDH Luxus water heater 9 12 15 18 21 24 Rated Power kW 9 12 15 18 21 24 Power Consumption at Characteristics I...

Page 4: ...return valve inlet and outlet pipes should not be made of plastic for economic reasons the heater should be installed in the vicinity of the most frequently used tap flow regulating valve should be i...

Page 5: ...allation should be equipped with safety power differential circuit breaker and other devices which will ensure disconnecting the heater from the source of power intervals between all their poles shoul...

Page 6: ...ng valve By regulation we understand setting optimal temperature of water by limiting the rate of flow To reach this purpose do the following shut off electric supplies undo the fixing screw 15 take t...

Page 7: ...ter installation according to directions in Venting section Fig 9 Filter cleaning 13 orifice 14 filter 17 inlet fitting cold water 20 gasket To assure faultless and long operation of the heater regula...

Page 8: ...gged hole for electric wires 5a hole for electric wires 7 back plate 13 orifice 15 fixing screws 16 catches 17 inlet pipe cold water 18 outlet pipe hot water 19 flow regulating valve XP electric termi...

Page 9: ...on power supplies the rate of flow through the heater is not sufficient filter blocked with impurities or incorrect setting of the flow regulating valve if the heating is weak or it does not heat up a...

Page 10: ...10 Water heater KDH Luxus 1 piece Gaskets 2 pieces Fixing hooks 2 sets Templet 1 piece Installation and operating instruction 1 piece Set contents...

Page 11: ......

Page 12: ......

Reviews: