Safety instructions

1.  Read and strictly follow the installation and operating instructions to ensure a 

long life and reliable unit operation.

2.  The unit is designed to be wall mounted.

3.  The  unit  can  only  be  used  when  in  perfect  technical  condition  and  correctly 

installed.

4.  If there is a non-return valve installed on the water supply pipe the safety valve 

must be fitted between the unit and non-return valve.

5.  Inlet and outlet pipes should not be made of plastic. This relates to KDH only.

6.  The unit should always be vented before initial start-up. Vent the unit each time 

after the water has been emptied from the heater or pipes (e.g. when water supply 

system has been repaired or maintained). 

7.  Connection to electrical system and measurement of fire protection effectiveness 

should be made by a qualified person.

8.  The unit has to be earthed or neutrally grounded.

9.  The unit must be permanently connected to the electrical system equipped with 

an earth clamp.

10.  Electric installation should be equipped with residual current protective devices 

and other solutions which will ensure disconnecting the heater from the source 

of power (intervals between all their poles should not be less than 3 mm).

11.  The unit must not be installed in the place which is exposed to the danger of 

explosion and place in which the temperature may go down below 0°C.

12.  It is not recommended to use mixer taps with thermostat.

13.  The unit must be kept in a place in which the temperature never goes down below 

0°C (there is a water inside the unit).

14.  The unit must be connected to the cold water supplies only.

15.  Do not use when the water has been emptied from the unit or pipes (e.g. when 

water supply system has been repaired or maintained).

16.  Unit’s cover must not be taken off while power is on.

17.  Failure to install the filter on water supply pipe can cause unit damage.

18  Accumulation of limescale in parts of the water heater may cause limited water 

flow and failure of the water heater. Failure of the heater and damages caused 

by the limescale will not be covered by the warranty. The water heaters and fit-

tings must be descaled on the regular basis, the frequency of limescale removal 

depanding on the quality of water.

19.   Appropriate precaution must be taken when using hot water. Temperature of 

water over 40°C may cause hot feeling and can be dangerous for children.

GB

Summary of Contents for KDH

Page 1: ...PPH2 KDH KDH2 Electric Instantaneous Water Heater GB FR Chauffe Eau Électrique Instantané ZBIORNIK BUFOROWY ...

Page 2: ...e supervised to ensure that they do not play with the appliance Cet appareil n est pas destiné à être utilisé par des personnes y compris des enfants dont les capacités physiques sensorielles ou mentales sont diminuées ou qui ne disposent pas des connaissances ou de l expérience nécessaire à moins qu elles n aient été formées et encadrées pour l utilisation de cet appareil par une personne respons...

Page 3: ...which will ensure disconnecting the heater from the source of power intervals between all their poles should not be less than 3 mm 11 The unit must not be installed in the place which is exposed to the danger of explosion and place in which the temperature may go down below 0 C 12 It is not recommended to use mixer taps with thermostat 13 The unit must be kept in a place in which the temperature n...

Page 4: ...o the water supply system 8 Open the cold water valve and check for leaks 9 Vent the unit See page 8 section Vent ing 10 Make sure that the WTC3 or WT3 temp limiter is at working position the knob should be pushed in 11 Put the unit s cover back 12 Make sure that there is no access to live parts through the holes at the back plate 2 3 1 Safety temperature limiter WTC3 WT3 a to switch on b WTC3 WT3...

Page 5: ...mperature range full power mode maximum power rated power There are two indicators on the case green power supply on red heating on Filter cleaning 1 Cut off power and cold water sup plies 2 Take off the unit s cover 3 Undo the inlet fitting from the orifice on the cold water side hold the orifice with spanner 22 4 Take the filter out from orifice 5 Clean up the filter 6 Fix the filter back 7 Do u...

Page 6: ...ltage 380V 3 Rated current A 3x13 7 3x18 2 3x22 8 3x27 3 3x31 9 3x36 5 Supply water pressure MPa 0 15 0 6 0 2 0 6 0 25 0 6 Operating point PPH2 KDH2 position I l min 1 9 2 3 3 2 3 6 4 3 KDH KDH 4 1 8 2 3 2 9 3 5 4 1 4 7 PPH2 KDH2 position II 3 1 3 8 4 7 5 1 6 1 KDH KDH 4 2 8 3 7 4 6 5 5 6 4 7 3 Efficiency at Δt 40 C and 0 4 MPa l min 3 3 4 3 5 4 6 5 7 6 8 7 Min connecting wires section mm2 4 x 1 5...

Page 7: ...re équipée d un dispositif de protection différentielle et les moyens permettant au chauffe eau de se déconnecter de la source d alimentation dont les pôles seront espacés de 3 mm minimum 11 Ne pas installer le chauffe eau dans des zones à risques d explosion et où la température peut tomber en dessous de 0 C 12 Robinet mitigeur thermostatique n est pas recommandée 13 Stockage de chauffe eau dans ...

Page 8: ...nne d arrivée d eau froid et vérifier l étanchéité 9 Purger l installation conformément au point PURGE 10 S assurer que interrupteur WTC3 ou WT3 est sur marche 11 Fixer le boîtier du chauffe eau 12 S assurer qu il n y a pas d accès aux éléments sous tension par derrière de chauffe eau 2 3 1 Interrupteur WTC3 WT3 a mise en marche de interrupteur b interrupteur en position marche broches pressée a b...

Page 9: ...ur vert raccordé au réseau électrique indicateur rouge chauffage Entretien Nettoyage du filtre d eau 1 Couper l alimentation électricité et l ar rivée d eau froide 2 Enlever boîtier du chauffe eau 3 Débrancher l arrive d eau froid du raccord d entrée du chauffe eau main tenez l orifice de avec le clés 22 4 Enlever le filtre à tamis sur arrivée d eau froide du réchauffeur 5 Nettoyer le filtre à tam...

Page 10: ...5 18 21 24 Alimentation 400V 3 Ampérage A 3x13 0 3x17 3 3x21 7 3x26 0 3x30 3 3x34 6 Pression d alimentation en eau MPa 0 15 0 6 0 2 0 6 0 25 0 6 Point d en clenchement du chauffage PPH2 KDH2 I étage de chauffage l min 1 9 2 3 3 2 3 6 4 3 KDH KDH 4 1 8 2 3 2 9 3 5 4 1 4 7 PPH2 KDH2 II étage de chauffage 3 1 3 8 4 7 5 1 6 1 KDH KDH 4 2 8 3 7 4 6 5 5 6 4 7 3 Débit avec augmentation de la température ...

Page 11: ...ou should contact the local government unit waste management service or the shop where this product has been purchased Ce produit ne doit pas être traité comme un déchet ordinaire L appareil démonté doit être ramené à un point de recyclage approprié pour les déchets électriques et électronique Le recyclage des produits n a pas d impact négatif sur l envi ronnement qui pourrait se produire dans le ...

Page 12: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl ...

Reviews: