Construction
6
Installer instruction manual
Fig.1 EKCO.T construction
[1] - water inlet
[2] - water outlet
[3] - heating box
[4] - power board
[5] - ZIO board
[6] - safety temperature limiter
[7] - automatic vent valve
[8] - flow sensor
[9] - safety valve
[10] - outlet temperature sensor
[11] - inlet temperature sensor
[12] - circulating pump
[13] - manometer
[14] - control board
[15] - electrical connector
PF - phase conductors connection point
WP - electric cable-bush
M - holes for boiler mounting
EKCO.T consists of the following
main parts:
- a heating box [3] to heat the
circulating medium,
- a control board [14],
- a circulating pump [12] to
force water to flow.
There are safety devices to protect
the boiler from failures and destruc-
tion:
- a safety temperature limiter [6],
cuts off power supply if water
reach temp. of 100
0
C, as a
result of it the boiler will shut
down (contact an authorised
service),
- a flow sensor [8], starts the
boiler if the correct flow is
reached,
- a safety valve [9] activates
if the pressure in the central
heating system goes over the
pressure limit (3 bar).