Page 1: ......
Page 2: ...same Used product can t be treated as general communal waste Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment for recycling Appropriate utilisa...
Page 3: ...uction 4 Installer instruction manual Technical data 5 Construction 6 Installation 7 Connection of external appliances 9 Start up 10 Advanced settings 11 User instruction manual Using a boiler 12 Fail...
Page 4: ...oiler intended for closed or opened central heating systems with forced circulation protected according to legally binding norms The boiler features automatic work control and low maintenance requirem...
Page 5: ...kg 29 Water connection G1 Safety class IP 21 Boiler type EKCO T 30 36 42 48 Rated power consumption kW 30 36 42 48 Rated voltage 400V Rated current A 3 x 43 3 3 x 52 0 3 x 60 6 3 x 69 3 Fuse rated cur...
Page 6: ...cable bush M holes for boiler mounting EKCO T consists of the following main parts a heating box 3 to heat the circulating medium a control board 14 a circulating pump 12 to force water to flow There...
Page 7: ...l heating installation scheme PI manometer ZK cut off valve F filter with magnetic insert RW expansion pipe NW expansion vessel ZT thermostatic radiator valve ZP passage valve G heater RP room program...
Page 8: ...system fig 1 4 6 Fix the room thermostat in accordance with manufacturer s instruction 7 Connect the room thermostat using two wires for instance 2 x 0 35 mm2 to the RP terminals fig 5a 8 Once you hav...
Page 9: ...o that when a master appliance gets on the contact will be opened the boiler switched off When the NA contact gets opened heating will get off and the pump stopped The EKCO boiler may also work as the...
Page 10: ...e it before to begin the special start up procedure Follow the above recommen dations otherwise we may not honour your warranty rights 6 7 Fig 6 Gear pump controller Fig 7 Pump venting Start up Specia...
Page 11: ...rom the unit and from left and right heating box operation in cascade connection r0 single unit work the master controller doesn t recognize the unit r1 cascade operation number of unit that works in...
Page 12: ...not cut power supply off between heat ing season When the control panel is switched to stand by mode all indicators are off In this mode the boiler is off but the pump is activated every day for 15 m...
Page 13: ...nel is not available You can set the temp directly on the cylinder thermostat You can check out the following working parameters by pressing the button A display shows in sequence 1 Next pressing of i...
Page 14: ...summer mode should be used after the heating season A water temp in cylinder is shown only if the WE 008 sensor is applied connected to the Tzas entry on the ZIO board To set the temp of water in cyli...
Page 15: ...nstallation a failure of electronic module contact an authorised service D indicator flickers a failure of inlet temp sensor boiler in failure condition contact an authorised service E indicator flick...
Page 16: ...ing Boiler kit This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl edge unless they have been give...
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......