3 -
(
) - inactive indicator.
4
- (
) - inactive indicator.
5
- (
) - Return temperature indicator.
- flickers- sensor failure.
6
- (
) - flow temperature indicator.
- flickers- sensor failure.
7
- (
) - Indicator of boiler activity (for central heating)
- red light- a boiler heats the medium.
- green light- proper temp. has been reached.
- off- boiler operates in summer mode.
8
- (
) - Indicator of boiler activity (for hot water cylinder)
- red light- , boiler is heating DHW.
- green light, proper. temp. has been reached
- off or flickers, DHW mode is disabled or time-blocked
9
- Control buttons.
10
- stand-by indicator
- flickers- boiler operates in stand-by mode
11
- 7-segment display.
kW
,
°C
,
bar
,
l/min
- Indicators showing which parameter is displayed on digital display (in order boiler power,
temperature, system pressure, flow of the medium).
NA
-
free-voltage entry,
master appliance connection point, Work without superior device need use a jumper.
RP
-
free-voltage entry
, room thermostat connection point. Work without room thermostat need to use
a jumper.
Tzas
- DHW temperature sensor or DHW thermostat connection. Set type of sensor in service menu or take off
without connecting.
Q -
flow sensor connection point.
Tin
- return temperature connection point.
Tout
- flow temperature connection point.
Ciś
- pressure sensor connection point.
ZM
- power board connection point.
Zaś
- Supply connection from power board (
N
- blue,
L
- red)
Pompa
- circulate pump connection (
N
- blue,
L
- red)
ZTD
- three-way valve connection Honeywell VC6012(work with DHW cylinder) (N – blue, LA- red, LB- brown)
3.c. Temperature settings (central heating).
Press
until only indicator
is illuminated. Press
or
until the desired temperature setting is
achieved. To switch to the main view press
button. A controller will switch over to the main view, if you don't
use a buttons for 1 min.
3.d. DHW cylinder settings.
Settings of water temperature in the DHW system with thermostat are set on thermostat.
We can set water temperature on boiler settings only on DHW system with sensor WE009