GUIDE GÉNÉRAL DES WATTS

Pièce 

Watts en marche 

Air conditionné (12000 Btu) (*) ........................... 1750 
Compresseur à air (1/2 HP) (*) .......................... 1400 
Compresseur à air (3/4 HP) (*) .......................... 1800 
Compresseur à air (1 HP) (*) ............................. 2000 
Chargeur de batterie (25A) .................................. 600 
Sableuse à ruban (3” ruban) .............................. 1000 
Scie circulaire (7 1/4”) ................................. 825-1050 
Cafetière ..................................................... 900-1100 
Taille bordure (gazon) .......................................... 550 
Ventilateur de fournaise (1/3 HP) (*) .................. 1200 
Réchaud (simple) ............................................... 1500 
Clef à impact ........................................................ 600 
Ampoule .................................................... Bulb rating 
Marteau pneumatique ........................................ 1200 
Micro-onde ........................................................... 750 
Fusil à peinture (1/3 HP) (*) ................................. 650 
Fusil à peinture, pulvérisateur manuel ................. 175 
Radio ............................................................... 50-200 
Réfrigérateur (*) ................................................... 600 
Banc de scie (10”) (*) ......................................... 2000 
Télévision ...................................................... 250-550 
Taille haies ........................................................... 500 
Note: (*) Les pièces ont besoin de 3 fois le  
wattage inscrit lors du démarrage. 

 
NOTE: Plusieurs appareils tels que les scies ou les 
perceuses demandent plus de courant qu’indiqué sur la 
plaque lorsque surchargés.  
 

DÉMARRER LA GÉNÉRATRICE 
 

Avant de démarrer votre génératrice, assurez-vous d’avoir 
suivi toutes les instructions des sections précédentes. 
 

 

Vérifier les niveaux d’huile et d’essence.  

  Ouvrir la valve d’essence sous le réservoir à 

essence.  

 

Ouvrir la valve d’essence sur le devant du moteur.  

  Déplacer le levier de l’« étrangleur » à l’avant en 

position « 

ON 

». Note: l’étrangleur n’est pas 

obligatoire si le moteur est chaud ou dans des 
températures ambiantes élevées.   

 

Remettre l’étrangleur à sa position initiale. 

 
 

DÉMARRAGE MANUEL 

 

 

Mettre l’interrupteur ON/OFF du moteur en position 
ON. 

 

Tirer le cordon de recul jusqu’à ce qu’une résistance 
ce fasse sentir, tirer ensuite fermement. Laisser le 
cordon revenir doucement pour ne pas le briser. 

 

Remettre l’étrangleur à sa position initiale. 

 

ATTENTION:

  Cette génératrice est équipée d’un 

système de protection d’huile. Le moteur s’éteint et/ou ne 
démarre pas lorsque le niveau d’huile est trop bas pour un 
usage sécuritaire. 
 

 
 
 
 

UTILISATION DE LA GÉNÉRATRICE 
 

Une fois en marche, allouer approximativement 3 minutes 
au moteur pour se stabiliser. Vérifier que les disjoncteurs 
et les réceptacles (prises femelles) GFCI sont correctes. 
 
 

ARRÊT DE LA GÉNÉRATRICE 
 

Débrancher tous les appareils et laisser la génératrice 
fonctionner sans charge pendant quelques minutes. 
Tourner la valve en avant du moteur en position OFF. 
Tourner le commutateur du moteur ON/OFF dans la 
position OFF. Tourner la valve d’essence au bas du 
réservoir d’essence en position OFF. 

ATTENTION

: Ne 

jamais utiliser l’étrangleur pour arrêter le moteur.  

 

USAGE DE LA GÉNÉRATRICE 

 

QU’EST-CE QU’UNE GÉNÉRATRICE?  
 

Une génératrice est principalement un moteur à essence 
ou au diesel couplé à un alternateur pour produire de 
l’électricité.  C’est une bonne alternative d’énergie 
lorsqu’il y a des pannes d’électricité ou encore lorsque 
vous êtes dans un endroit éloigné où l’électricité n’est pas 
disponible. Les génératrices sont indispensables pour les 
gens comme les agriculteurs ou les entrepreneurs qui ont 
souvent besoin d’une source portable d’électricité. Elles 
sont également très utiles pour un usage récréatif.  
 
 

CHOISIR UNE GÉNÉRATRICE 
 

Le choix de la bonne génératrice est important. Une 
génératrice trop petite pour alimenter vos équipements ne 
pourra pas les faire fonctionner tous, alors qu’une 
génératrice trop grosse coûte plus cher et représente une 
perte d’argent lorsqu’elle ne fonctionne pas à son plein 
potentiel. La grosseur de génératrice adéquate peut être 
déterminée en additionnant les watts de chaque article à 
employer simultanément avec les watts nécessaires à 
l’allumage.   Sélectionner une génératrice avec un taux 
continu qui dépasse votre total de 20% afin de permettre 
une expansion éventuelle. Voir le tableau de la section 
intitulée « Surcharge de la génératrice » pour les normes 
d’équipements fréquemment utilisées.  
 

WATTS CONTINU versus WATTS MAXIMUM  
 

Les watts nominaux ou continus sont le nombre de watts 
nécessaires à un équipement lorsqu’il fonctionne.  
Les watts de surtension ou maximums sont le nombre de 
watts requis pour démarrer un équipement.  
Cette information est habituellement inscrite sur la plaque 
du manufacturier. Si les watts ne sont pas inscrits, ils 
peuvent être calculés en utilisant la formule suivante: 
watts = ampères x volts. 
 

 
 
 
 
 
 

Summary of Contents for GEH-3100DX

Page 1: ...or in the spaces provided below Retain these numbers for future reference The Model and Serial numbers are located on the generator data plate on the alternator case or generator frame along with othe...

Page 2: ...English 0069297 2 CONTACT INFORMATION For Parts Service or your nearest distributor call Koshin America Customer Service 1 800 634 4092 Website www koshinamerica com...

Page 3: ...LY INSPECTION 16 FAULT FINDING GUIDE 16 PARTS ORDERING 17 GENERATOR PARTS LISTS 19 GEH 3100DX GENERATOR PARTS LIST 19 WIRING SCHEMATICS 21 FRENCH INSTRUCTIONS 22 S CURIT 22 INFORMATION GENERALE 22 r g...

Page 4: ...Carga DE su generador 44 limitaciones del motor y rendimiento del generador 44 limpieza del generador 44 detalles de receptaculos 44 MANTENIMIENTO GENERAL 45 especificaciones y capacidades del motor 4...

Page 5: ...ts or other reproductive harm ELECTROCUTION DANGER THIS GENERATOR SET PRODUCES ELECTRICAL CURRENT THEREFORE SAFETY GUIDELINES MUST BE FOLLOWED IMPROPER USE OF THIS GENERATOR CAN RESULT IN ELECTROCUTIO...

Page 6: ...E GENERATOR AT SPEEDS BELOW THE NOMINAL 3600 RPM COULD CAUSE DAMAGE TO THE GENERATOR OR DRIVEN APPARATUS DUE TO LOW VOLTAGE OUTPUT WARNING REFER TO LOCAL AND NATIONAL ELECTRICAL CODES TO DETERMINE GRO...

Page 7: ...s of normal maintenance or replacement repair of normal wear parts 3 Any failure caused by contaminated fuels oils or lack of proper fuels oils 4 Failures caused by any external cause or act of God su...

Page 8: ...gistration Form in this section keep a copy for your records and mail form to Koshin America Corporation 1218 Remington Rd Schaumburg IL 60173 Customer Service 1 800 634 4092 e mail CustomerService Ko...

Page 9: ...From Address City State Zip Date of purchase Product Details Model Number Serial Number Are you satisfied with the product you purchased Yes No When you need to replace your machine will you consider...

Page 10: ...English 0069297 10 fold Koshin America Corporation 1218 Remington Rd Schaumburg IL 60173 Customer Service 1 800 634 4092 e mail CustomerService KoshinAmerica com Place Stamp Here...

Page 11: ...manual or other information provided by the engine manufacturer supersedes data provided here Proper oil grade varies with climate The grade listed in the table is typically a good grade but consult t...

Page 12: ...3 minutes Check that the circuit breakers and the GFCI receptacles are not tripped STOPPING THE GENERATOR SET Unplug all appliances and let the engine run unloaded for a couple of minutes Turn the fu...

Page 13: ...mperatures above 60 F 20C or above Sea Level will result in lower electrical output Electrical output must be derated 1 for each 10 F above 60 F and 3 for each 1000 feet above mean sea level GENERATOR...

Page 14: ...rovided with each machine that also provides basic maintenance and troubleshooting information Defer to the engine manufacturers manual if any discrepancies appear between the data provided in this ma...

Page 15: ...table below to select the proper oil for the temperature in your area Viscosity 30C 22F 20C 4F 10C 14F 0C 32F 10C 50F 20C 68F 30C 86F 40C 104F Single 10W 20W 20 30 40 Multi 20W 40 20W 50 15W 40 15W 5...

Page 16: ...breaker tripped 2 GFCI receptacle tripped 3 Faulty circuit breaker 4 Faulty receptacle 5 Faulty capacitor in alternator 6 Faulty diodes in alternator 7 Failure in alternator windings 1 Reset circuit...

Page 17: ...ifier may be followed by words or abbreviations such as upper lower inner outer front rear RH LH etc when they are essential MARKINGS AND DECALS NOTE Do not paint over safety warnings or instructional...

Page 18: ...o purchase order can be received by the Company the additional charges will be honored by the Purchaser Warranty The Company warrants that parts manufactured by it will be as specified and will be fre...

Page 19: ...Muffler 17 5 0000992 Flatwasher M8 5 16 5 1 G51398 11 Liter Tank 18 12 G020803 Flange Bolt M6x16 Z 6 1 GU0025 Fuel Cap 19 9 G034909 M6 Cage Nut 7 1 Alternator Model ES80B 20 4 GU0149 Flange Bolt M6x20...

Page 20: ...GEH 3100DX GENERATOR PARTS 0069297 20 GA9502 G071410 G071406 G034909 G075239 G075766 G075532 G041308 GU0184 G034308 G92729 0000992 5 16 0004416...

Page 21: ...English 21 WIRING SCHEMATIC GEH 3100DX...

Page 22: ...la garantie AVERTISSEMENT Le tuyau d chappement de ce produit contient des produits chimiques qui sont reconnus par l tat de Californie comme pouvant causer le cancer des anomalies cong nitales ou d...

Page 23: ...CONNA TRE LA CHARGE LECTRIQUE TOTALE ET ELLE NE DOIT PAS D PASSER LA CAPACIT D TERMIN E DE LA G N RATRICE SI L APPAREIL UTILIS N AFFICHE PAS LES WATTS MAIS SEULEMENT L AMP RAGE LES WATTS PEUVENT TRE C...

Page 24: ...ET PEUT CAUSER DES BLESSURES S RIEUSES AVERTISSEMENT TOUJOURS D BRANCHER LE C BLE DU P LE N GATIF DE LA BATTERIE AVANT DE FAIRE L ENTRETIEN DE LA BATTERIE OU AVANT FAIRE N IMPORTE QUEL ENTRETIEN LECTR...

Page 25: ...ate Zip Date of purchase Product Details Model Number Serial Number Are you satisfied with the product you purchased Yes No When you need to replace your machine will you consider another Koshin produ...

Page 26: ...French 0069297 26 pliez Koshin America Corporation 1218 Remington Rd Schaumburg IL 60173 Customer Service 1 800 634 4092 e mail CustomerService KoshinAmerica com Affranchir suffisamment...

Page 27: ...or replacement repair of normal wear parts 3 Any failure caused by contaminated fuels oils or lack of proper fuels oils 4 Failures caused by any external cause or act of God such as but not limited t...

Page 28: ...mation fournie par le manufacturier du moteur remplace les donn es fournies La qualit d huile ad quate varie selon le climat La qualit num r e dans le tableau est ad quate mais consulter tout de m me...

Page 29: ...les prises femelles GFCI sont correctes ARR T DE LA G N RATRICE D brancher tous les appareils et laisser la g n ratrice fonctionner sans charge pendant quelques minutes Tourner la valve en avant du mo...

Page 30: ...e de la tension lectrique La tension lectrique doit tre d grev de 1 pour chaque 10 F au dessus de 60 F et de 3 pour chaque 1000 pieds au dessus du niveau de la mer NETTOYAGE DE LA G N RATRICE ATTENTIO...

Page 31: ...fourni avec chaque appareil et il fournit galement les informations d entretien g n rales ainsi que des informations sur les probl mes techniques Si les informations contenues dans ce manuel diff rent...

Page 32: ...s servir du tableau ci contre pour s lectionner la bonne huile pour la temp rature de votre r gion Viscosit 30C 22F 20C 4F 10C 14F 0C 32F 10C 50F 20C 68F 30C 86F 40C 104F Simple 10W 20W 20 30 40 Multi...

Page 33: ...disjoncteur est saut 2 R ceptacle GFCI saut 3 disjoncteur d fectueux 4 r ceptacle d fectueux 5 Condensateur de l alternateur d fectueux 6 diodes de l alternateur d fectueux 7 d fauts dans le circuit...

Page 34: ...ctions Commander des d calques de rechange aupr s de l usine d s qu ils deviennent illisibles Le num ro de la pi ce pour les d calques originaux et leurs locations sont illustr s dans la section des p...

Page 35: ...l acheteur Garantie La Compagnie garantie les pi ces qu elle usine tel que sp cifi es et seront exemptes de d fauts mat riels et de main d uvre La responsabilit de la Compagnie sous cette garantie ne...

Page 36: ...ectos al nacer u otros da os reproductivos ELECTROCUCION PELIGRO ESTE GENERADOR PRODUCE CORRIENTE ELECTRICAT POR LO TANTO LAS GUIAS DE SEGURIDAD DEBEN DE SEGUIRSE USO INAPROPIADO DE ESTE GENERADOR PUE...

Page 37: ...OS CAUTION DO NOT TAMPER WITH THE ENGINE GOVERNED SPEED THE GENERATOR OPERATES AT A NOMINAL SPEED OF 3600 RPM INCREASES IN SPEED OVER THE 3600 RPM NOMINAL WILL INCREASE THE CHANCE OF PERSONAL INJURY D...

Page 38: ...ENERADOR O MOTOR REGISTRACION DE GARANTIA Registro Completa de Maquinas Maquinas enviadas dentro de los Estados Unidos no requieren registro de garant a a menos que el estatus cambia por ejemplo cambi...

Page 39: ...State Zip Date of purchase Product Details Model Number Serial Number Are you satisfied with the product you purchased Yes No When you need to replace your machine will you consider another Koshin pr...

Page 40: ...Espanol 0069297 40 doble Koshin America Corporation 1218 Remington Rd Schaumburg IL 60173 Customer Service 1 800 634 4092 e mail CustomerService KoshinAmerica com Coloque La Estampilla Aqui...

Page 41: ...ra de ejercitarse la garant a La garant a arriba no aplica a fallas ocurridas por resultado de abuso emplear mal reparaciones negligentes corrosi n erosi n y deterioro y roturas normales alteraciones...

Page 42: ...ormaci n proporcionada por el fabricante del motor reemplaza los datos dados aqu Grado apropiado de aceite var a seg n el clima El grado en la lista de abajo es t picamente un buen grado pero consulte...

Page 43: ...Una vez encendido permita que el motor se estabilice por aproximadamente 3 minutos Compruebe que los interruptores y el enchufe GFCI no est n disparados APAGADO DEL GENERADOR Desenchufe los aparatos y...

Page 44: ...C o por encima del nivel del mar puede resultar en una reducci n de la potencia el ctrica La potencia el ctrica debe ser reducida un 1 por cada 10 F por encima de 60 F y 3 por cada 1000 pies por encim...

Page 45: ...Max HP 5 5 hp 3600rpm Max Troqu 8ft lb 2500rpm Proporci n de Compresi n 8 5 1 Sistema de Enfriamiento Forced air Sistema de Ignici n Transistorized magneto Tiempo de Ignici n 25 B T D C fixed Buj a B...

Page 46: ...e arranque apagado 4 Sistema de Combustible Cerrado Con Fugas 5 Filtro de aire atascado 6 Generador bajo carga al arranque 1 Rellene con Aceite 2 Rellene con Combustible Prenda v lvulas 3 Prenda el In...

Page 47: ...el nombre siempre es la primera parte de la descripci n El nombre generalmente es seguido por un modificador individual descriptivo El modificador descriptivo puede ser seguido de una palabra o abrevi...

Page 48: ...rtaci n o tardanzas en parte del suplidor de la compania u otras causas fuera del control de la compania Si el Comprador requiere instrucciones especiales de embarque como uso exclusivo de facilidades...

Reviews: