step 1
Remove the air conditioner from it’s packaging, remove fixing
screws and slide the air conditioner out of it’s housing (Refer
to Installation Steps).
step 2
Prepare the hole in the wall so that the bottom of the housing
is well supported, the top has minimum clearance and the air
inlet louvers have clearance as shown below in options A and
B. Holes from the outside through to the cavity should be
sealed. The housing should slope down towards the rear by
about 5mm to allow water formed during operation to drain.
step 3
Install the housing into the wall and secure. Ensure the foam
seals are not damaged. Flash, seal or fill gaps around
the inside and outside to provide satisfactory appearance
and protection against the weather, insects and rodents.
Installation of the Housing
Installation of the unit into the Housing
1. Slide the unit into the housing until it is firmly against the
rear of the housing. Care is required to ensure the foam
sealing strips on the housing remain in position.
2. Connect the air conditioner to the power and position
excess cord length beneath the air conditioner base.
3. Engage the chassis fixing brackets into the bottom housing
rail and secure to the base with the screw provided.
4. Remove the front panel from it’s carton and plastic bag
and fit as per the Installation lnstruction.
5. Switch unit on. Check for operation of the unit and check
for vibration in the installation.
6. Fit the drain pan to the housing and run a drain line to a
suitable location if required.
NOTE: UNIT MAY BE SUPPORTED BY A
SOLID FRAME FROM BELOW
ORBY A HANGER FROM A
SOLID OVERHEAD SUPPORT.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME ALL ROUND
UNIT
TIMBER FRAMED
WALL OR PARTITION
EXTERNAL SUPPORT
FRAME AT BALANCE
POINT OF A/C
ALTERNATIVELY, BRACKETS
AS ILLUSTRATED BELOW
MAY BE USED.
DRAIN PAN
Alternative method of installation if external
support cannot be provided.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
FRAME
TIMBER FRAMED
WALL OR PARTITION
SOLID TIMBER SUPPORT
STEADYING BRACKET
(ONE PER SIDE)
DRAIN PAN
ENSURE LOUVRES
ARE ENTIRELY
OUTSIDE THE WALL
Preferred method of installation into a timber
framed wall, partition or window.
Installations of the unit into the wall
AIR IN
AIR IN
AIR OUT
100mm minimum
AIR IN
OPTION A
OPTION B
LOUVRE
BRICK
WALL
45
O
BRICK CUT AWAY
TO CLEAR LOUVRES
FRONT
AIR OUT
AIR IN
AIR IN
TOP
VIEW
45
O
BRICK CUT AWAY
TO CLEAR LOUVRES
100mm
BRICK
WALL
100mm
14