background image

step 1

Remove the air conditioner from it’s packaging, remove fixing

 

screws and slide the air conditioner out of it’s housing (Refer 

to Installation Steps).

step 2

Prepare the hole in the wall so that the bottom of the housing 

is well supported, the top has minimum clearance and the air 

inlet louvers have clearance as shown below in options A and 

B. Holes from the outside through to the cavity should be 

sealed. The housing should slope down towards the rear by 

about 5mm to allow water formed during operation to drain.

step 3

Install the housing into the wall and secure. Ensure the foam 

seals  are  not  damaged.  Flash,  seal  or  fill  gaps  around 

the inside and outside to provide satisfactory appearance  

and protection against the weather, insects and rodents.

Installation of the Housing 

Installation of the unit into the Housing 

1.  Slide the unit into the housing until it is firmly against the   

 

   rear of the housing. Care is required to ensure the foam     

  sealing strips on the housing remain in position.

2. Connect the air conditioner to the power and position   

  excess cord length beneath the air conditioner base.

3.  Engage the chassis fixing brackets into the bottom housing 

 

  rail and secure to the base with the screw provided.

4.  Remove the front panel from it’s carton and plastic bag   

  and fit as per the Installation lnstruction.

5.  Switch unit on. Check for operation of the unit and check   

  for vibration in the installation.

6.  Fit the drain pan to the housing and run a drain line to a     

  suitable location if required.

NOTE:  UNIT MAY BE SUPPORTED BY A 

 

            SOLID  FRAME  FROM  BELOW 

 

 

ORBY  A  HANGER  FROM  A 

 

 

SOLID OVERHEAD SUPPORT.

 

FLASH OR SEAL AROUND EXTERNAL 

WALL FRAME OR ARCHITRAVE

STURDY TIMBER

FRAME ALL ROUND 

UNIT

TIMBER FRAMED 

WALL OR PARTITION

EXTERNAL SUPPORT 

FRAME AT BALANCE

POINT OF A/C

ALTERNATIVELY, BRACKETS 

AS ILLUSTRATED BELOW

MAY BE USED.

DRAIN PAN

Alternative method of installation if external 

support cannot be provided.

FLASH OR SEAL AROUND EXTERNAL 

WALL FRAME OR ARCHITRAVE

STURDY TIMBER

FRAME

TIMBER FRAMED 

WALL OR PARTITION

SOLID TIMBER SUPPORT

STEADYING BRACKET

(ONE PER SIDE)

DRAIN PAN

ENSURE LOUVRES

ARE ENTIRELY 

OUTSIDE THE WALL

Preferred method of installation into a timber 

framed wall, partition or window.

Installations of the unit into the wall 

AIR IN

AIR IN

AIR OUT

100mm minimum

AIR IN

OPTION A

OPTION B

LOUVRE

BRICK

WALL

45

O

 BRICK CUT AWAY 

TO CLEAR LOUVRES

FRONT

AIR OUT

AIR IN

AIR IN

TOP

VIEW

45

O

 BRICK CUT AWAY 

TO CLEAR LOUVRES

100mm

BRICK

WALL

100mm

14

Summary of Contents for kwr09a02s

Page 1: ...Before using the unit read this user s manual carefully which provides important information concerning the proper operation of the unit User s MANUAL...

Page 2: ...Dear Customer Congratulations Thank you for buying this KORYO appliance Your new Window Air Conditioner has been designed for your convenience We are sure you will get many years of trouble free servi...

Page 3: ...an for repair or maintenance of this unit Contact the Koryo authorized service engineer for the installation of this unit The air conditioner is not intended for use by young children or any mentally...

Page 4: ...fire and electric shock It may cause electric shock Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause an explosion or fire 4 Do not modify...

Page 5: ...of air outlet Always insert the filters securely Clean filter once every two weeks Do not drink water drained from air conditioner Do not place heavy object on the power cord and ensure that the cord...

Page 6: ...ncy ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants an...

Page 7: ...wn Fig 1 1 Power cord conductors are distinguished according to color as follows see Fig 1 2 For your safety and protection this unit is earthed through the power cord see Fig 2 Please contact Koryo a...

Page 8: ...right position To close it set the lever in the left position CLOSE VENT OPEN CLOSE OPEN SWING SWING FAN TIMER SLEEP POWER MODE C COOL DRY FAN HIGH MED LOW TEMP OPERATING INSTRUCTIONS POWER Press the...

Page 9: ...stops when the room temperature is 1O C below the set point The fan will not stop running AUTO The fan motor remains on MED speed in AUTO mode The unit will select the appropriate operating mode from...

Page 10: ...WER Turns the power to the main unit on off only MODE Activates the AUTO if applicable COOL FAN or DRY function TIMER Activates the auto START or auto STOP program from 0 12 hours 1 hour increments SL...

Page 11: ...buttons to select increase decrease the required operating temperature the selected temperature will appear temporarily in the LED display The temperature settings are adjustable between 16O C to 31O...

Page 12: ...pside 3 Clean the filter with warm soapy water The water should be below 40 C to prevent distortion of the filter 4 Rinse off and gently shake off excess water from the filter Allow the filter to dry...

Page 13: ...1 To avoid vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build...

Page 14: ...brackets into the bottom housing rail and secure to the base with the screw provided 4 Remove the front panel from it s carton and plastic bag and fit as per the Installation lnstruction 5 Switch uni...

Page 15: ...n the chassis and carefully slide the air conditioner out of the cabinet See Fig 6 3 Remove shipping pad from around compressor before operation and make sure the discharge points to the drain pan are...

Page 16: ...ker If power failure occurs switch off and disconnect unplug the power cord When power is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditione...

Page 17: ...ditioner in your house after it becomes non operational or after it suffers any accidental breakage or damege DISPOSAL This symbol on the product or on the container indicates that this product cannot...

Page 18: ...arranty shall automatically expire by efflux of time on completion of the period indicated herein above and no notice of such expiry will be given by the Company 3 This warranty shall stand automatica...

Page 19: ...providing any warranty under the following situations i Any damage caused by accident mishandling tampering with installation or negligent in following instructions of the user manual issued by the C...

Page 20: ...ixer Grinders Window Conditioners Pop Up Toasters Mixer Grinders Storage Water Heaters Sandwich Makers Juice Extractors Instant Water Heaters Induction Cook Tops Food Processors Immersion Heater Elect...

Reviews: