Instruction Manual
ENGLISH
25
REFRIGERANT
The refrigerant used in this mobile air conditioner is R290. The
refrigerant used is less than 1 kg and is in a closed refrigerant
circuit.
Caution, risk of fire! R290
Any person who is involved with working on or breaking into
a refrigerant circuit should hold a current valid certificate from
an industry-accredited assessment authority, which authorizes
their competence to handle refrigerants safely in accordance
with an industry recognized assessment specification.
Any repairs you need, contact the nearest authorized Service
centre and strictly follow manufacturer’s instruction only.
WARNING:
•
Appliance shall be installed,operated and stored in a room
with a floor area larger than 11m² .
•
Do
not
use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
•
The appliance shall be stored in a room without continuously
operating ignition sources(for example:open flames,an
operating gas appliance or an operating electric heater).
•
Do
not
pierce or burn.
•
Be aware that refrigerants do
not
have any odour.
Summary of Contents for 82002
Page 184: ...Ref 82002 2020 01...