1. Set the knobs as follows (Standard Setting)
2. CV Offset Adjustment
Connect the voltmeter to CV OUT (Hz/V)
1. Press the C3 key (the leftmost C key), and
adjust the trim pot PT1
to get 1.000V from the CV OUT (Hz/V).
2. Press the C6 key (the rightmost C key), and
adjust the trim pot PT13
to get 8.000V from CV OUT (Hz/V)
Repeat 1 and 2 above so that
pressing the C3 key generates 1.000V, and
pressing the C6 key generates 8.000V.