AX3000G / 3000B TEST MODE instructions
How to start
Turn the power
on by pressing following switches for each operation as follows.
LCD shows AX3000G (or AX3000B) and software version number.
Each checking mode starts when you release from those switches.
Switches (to press)
Modes
[INTERNAL CHECK] C EXP/CTL
Internal check
→
Operation Check
[OPERATION CHECK] PRE FX + MODULATION
Operation Check
[MIDI CHECK]
AMP/LINE + WRITE
MIDI Check
→
Audio Check
INTERNAL CHECK
Before the power on, please connect the testing cable into both PHONE and INPUT jack. Also,
put another testing cable into SEND and RETURN jack. Then rotate the LEVEL knob (next to
PHONE jack) into maximum.
The following inspection items are run automatically.
During the procedure, item number and step are shown on BANK LED.
If any item is NG (no good), item name with NG is shown on LCD and BANK LED (item number
and step number) stops with blinking.
Item
Step
Display on NG
1. I2C I/F (EEP ROM)
1. EEPROM
EEP IC2
1. DSP Serial I/F
DI/F IC2
2. DSP
2. DSP IRQ Port I/F
DIRQ IC2
1. Data Bus
RDAT IC1
3. DSP DRAM
2. Adress Bus
RADR IC1
4. CODEC POWER DOWN 1. CODEC POWER DOWN
MUTE IC5
1. So1L --> Si1R
LVL L->R
2. So1L --> Si1L
LVL L->L
3. So1R --> Si1R
LVL R->R
4. So1R -> SEND -> RETURN -> Si1R
LVL RTN
5.RET RMVE(Plug off RETURN jack)
----
5. LEVEL
6. So1R --> Si1R
LVL IN
Summary of Contents for AX3000B
Page 2: ...X 3570 BLK sch 1 Thu Dec 08 14 53 38 2005...