AIR-SEP

 Modbus RTU interface (RS485) 

 

Page 10 

KOREX Verfahrenstechnik GmbH 

 

You are now on the user interface of the   
Modbus RTU. 
 
For checking purposes, you will find bottom left of the 
display the network number and the name: "AS-Modbus 
RTU"  
 
Swipe upwards, touch the "

User" 

button and then 

"Technician"

 to register as an technician.   

 

The technician password is: "1962" 
 

Then, click the 

blue arrow

 to return to the main menu 

again.  

 

 

 

Via the "

Modbus

" you can access the Modbus setting 

parameters.    
 

 
 

 

 

From here on follow the instructions of 

3.1.1 Modbus- 

settings 

from page 7. 

 

4. 

Connection of Modbus line

 

Connection of Modbus line with due regard to the polarity 

(A/+/1, B/-/2)

 

Every Modbus network must be provided with a 
120I bus termination at the first and last 
network subscriber (terminate by jumper).  
It means that a Modbus network always comes 
with two terminating resistors (at the end in 
each case).     

The Modbus line needs to be laid in 
accordance with the Modbus guidelines.   

 

 

 

/ Termination 

Summary of Contents for AIR-SEP

Page 1: ...AIR SEP Modbus RTU Interface RS485 Supplementary Instructions Manual AS MBRTU Version 1 00 GB www korex de...

Page 2: ...AIR SEP Modbus RTU interface RS485 Page 2 KOREX Verfahrenstechnik GmbH...

Page 3: ...4 1 1 Liability and warranty 4 1 2 Symbols used 4 1 3 Intended use 5 2 Scope of supply 5 3 Modbus parameters 5 3 1 Settings by use of optional interface 7 3 1 1 Modbus settings 8 3 1 2 Modbus outputs...

Page 4: ...ngible assets can be impaired No modifications of the interface must be made The manufacturer will accept no liability and warranty for damage caused by one or several reasons as set out below Imprope...

Page 5: ...espond The Slaves cannot communicate with each other They can also not start a communication with the Master 2 Scope of supply The Modbus RTU item No AS MBRTU is already fitted to the AIR SEP device a...

Page 6: ...rent output are available in a different form have been added or dropped completely The parameters actually available can be gathered from the Modbus output live at the controller MV magntic valve Res...

Page 7: ...having set the optional AIR SEP SmartControl interface the CAN Bus button gives access to the list of devices and interfaces available in the network Click the button of the Modbus RTU interface A new...

Page 8: ...k 3 1 2 Modbus outputs Exception Code displays OK The value query from the Slave device was successful No respond No response from Slave device Reasons Modbus settings do not coincide with the Slave d...

Page 9: ...You will see the following picture deviations are possible Touch the display somewhere and keep your finger on the display for about 5 seconds IMPORTANT Four new buttons will occur Touch the left butt...

Page 10: ...w to return to the main menu again Via the Modbus you can access the Modbus setting parameters From here on follow the instructions of 3 1 1 Modbus settings from page 7 4 Connection of Modbus line Con...

Page 11: ...AIR SEP Modbus RTU Interface RS485 www korex de Page 11 Space for notes...

Page 12: ...interface RS485 Page 12 KOREX Verfahrenstechnik GmbH KOREX Verfahrenstechnik GmbH Talhofstrasse 30 82205 Gilching Munich Germany Tel 49 0 8105 77822 10 Fax 49 0 8105 77822 20 E Mail info korex de Int...

Reviews: