KOREX AIR-SEP Supplementary Instructions Manual Download Page 1

 

 

 
 
 
 

AIR-SEP

 

Modbus RTU Interface (RS485)

 

 
 

Supplementary Instructions Manual 

AS-MBRTU 

 
 

 

 
 

 
 
 
 
 
 
 
Version 1.00 GB

 

 

www.korex.de 

Summary of Contents for AIR-SEP

Page 1: ...AIR SEP Modbus RTU Interface RS485 Supplementary Instructions Manual AS MBRTU Version 1 00 GB www korex de...

Page 2: ...AIR SEP Modbus RTU interface RS485 Page 2 KOREX Verfahrenstechnik GmbH...

Page 3: ...4 1 1 Liability and warranty 4 1 2 Symbols used 4 1 3 Intended use 5 2 Scope of supply 5 3 Modbus parameters 5 3 1 Settings by use of optional interface 7 3 1 1 Modbus settings 8 3 1 2 Modbus outputs...

Page 4: ...ngible assets can be impaired No modifications of the interface must be made The manufacturer will accept no liability and warranty for damage caused by one or several reasons as set out below Imprope...

Page 5: ...espond The Slaves cannot communicate with each other They can also not start a communication with the Master 2 Scope of supply The Modbus RTU item No AS MBRTU is already fitted to the AIR SEP device a...

Page 6: ...rent output are available in a different form have been added or dropped completely The parameters actually available can be gathered from the Modbus output live at the controller MV magntic valve Res...

Page 7: ...having set the optional AIR SEP SmartControl interface the CAN Bus button gives access to the list of devices and interfaces available in the network Click the button of the Modbus RTU interface A new...

Page 8: ...k 3 1 2 Modbus outputs Exception Code displays OK The value query from the Slave device was successful No respond No response from Slave device Reasons Modbus settings do not coincide with the Slave d...

Page 9: ...You will see the following picture deviations are possible Touch the display somewhere and keep your finger on the display for about 5 seconds IMPORTANT Four new buttons will occur Touch the left butt...

Page 10: ...w to return to the main menu again Via the Modbus you can access the Modbus setting parameters From here on follow the instructions of 3 1 1 Modbus settings from page 7 4 Connection of Modbus line Con...

Page 11: ...AIR SEP Modbus RTU Interface RS485 www korex de Page 11 Space for notes...

Page 12: ...interface RS485 Page 12 KOREX Verfahrenstechnik GmbH KOREX Verfahrenstechnik GmbH Talhofstrasse 30 82205 Gilching Munich Germany Tel 49 0 8105 77822 10 Fax 49 0 8105 77822 20 E Mail info korex de Int...

Reviews: