The JetNet 6810G only supports single power input that binds V1 and V2 together to obtain
higher current for the booster.
Use the UL listed Switching power supply to power the JetNet Switch. For the power wiring
method, please refer to the figures 3.1-1 and 3.1-2. For system safety and the anti-immunity
ability, the chassis ground screw should be well grounded to the earth ground.
Figure 3.1-1. Power Supply wiring architecture
Note:
E.G: Earth
Grounding
Figure 3.1-2 Power connector assembly diagram
The RS-232 console and the alarm relay are
connected via the assembly type of 5-pole M12
A-coding connector included in the supplied
package of JetNet switch. The following figure
3-2-1 is the disassembly diagram of M12
A-coding connector.
In the M12 connector packing, the parts 1, 2, 3
are already assembled.
Follow the steps for soldering and assembling
the cable and connector together:
Figure 3.2-1 Field Assemble
M12 disassembly connector
3.2 RS-232 console and Relay Output Connection
Summary of Contents for JetNet 6710G