Setting at the front setting panel in front panel
:
Refer to P7
『
Name of parts
』
,
『
Setting panel
』
2-3 투출 종류 및 투출 시간 변경방법
How to set, change and check the function code
:
Function code listing and content display
2-3. How to set and check the function code
[Setting functions]
F0
F6
F1
F7
F2
F8
F3
F9
F4
Fb
F5
Geared Motor Accumulated use time
Ice outputting time (ice button)
Evaporator outlet temperature (
℃
)
Inner temperature of the product (
℃
)
Dispensing Standard type
Condenser temperature (
℃
)
Water outputting time (ice+water button)
Accumulated time of power-up
Water outputting time (iwater button)
Mode of automatic drainage
Ice outputting time (ice+water button)
Function to select
Select button
Press “SELECTION” button until the F0 appears.
F0
F6
F1
F7
F2
F8
F3
F9
F4
Fb
F5
Geared Motor Accumulated use time
Ice outputting time (ice button)
Evaporator outlet temperature (
℃
)
Inner temperature of the product (
℃
)
Dispensing Standard type
Condenser temperature (
℃
)
Water outputting time (ice+water button)
Accumulated time of power-up
Water outputting time (iwater button)
Mode of automatic drainage
Ice outputting time (ice+water button)
Press “SELECTION” button for 3 seconds to complete
the setting.
F1
Function for changing
the outputting time
(second ) of ice
*Default:1.0
(
Factory default
)
*Range of outputting
time: 0.1
~
9.9 seconds
Press “SELECTION” button until the F0 appears.
Press '+,- button to select F1.
Function to select
Select button
F0
Dispensing setting basic
type
:
select mainly use
function
00: Ice
01: Ice+Water
02: Water
Press “SELECTION” button until the F0 appears.
Press '+,- button and select F0.
Press “SELECTION” button for 1 second, the number
will be displayed.
Press “SELECTION” button for 1 second, the number
1.0 will be displayed.
Press '+,- button and select desired outputting type. (By
each press of the button, the number will be displayed
sequentially.)
Press “SELECTION” button for 3 seconds to complete
the setting.
Press '+,- button to select desired outputting type. (By
pressing the button 00,01,02 will be displayed
sequentially
)
10
F0
F6
F1
F7
F2
F8
F3
F9
F4
Fb
F5
Geared Motor Accumulated use time
Ice outputting time (ice button)
Evaporator outlet temperature (
℃
)
Inner temperature of the product (
℃
)
Dispensing Standard type
Condenser temperature (
℃
)
Water outputting time (ice+water button)
Accumulated time of power-up
Water outputting time (iwater button)
Mode of automatic drainage
Ice outputting time (ice+water button)
Press “SELECTION” button for 3 seconds to complete
the setting.
F1
Function for changing
the outputting time
(second ) of ice
*Default:1.0
(
Factory default
)
*Range of outputting
time: 0.1
~
9.9 seconds
Press “SELECTION” button until the F0 appears.
Press '+,- button to select F1.
Function to select
Select button
F0
Dispensing setting basic
type
:
select mainly use
function
00: Ice
01: Ice+Water
02: Water
Press “SELECTION” button until the F0 appears.
Press '+,- button and select F0.
Press “SELECTION” button for 1 second, the number
will be displayed.
Press “SELECTION” button for 1 second, the number
1.0 will be displayed.
Press '+,- button and select desired outputting type. (By
each press of the button, the number will be displayed
sequentially.)
Press “SELECTION” button for 3 seconds to complete
the setting.
Press '+,- button to select desired outputting type. (By
pressing the button 00,01,02 will be displayed
sequentially
)