4. CARE AND MAINTENANCE

Cleaning Your Air Filters

A dirty air filter will cause a reduction of airflow.  Reduction of airflow causes overloading 
and consumes more electricity.  Therefore, regular cleaning is necessary for efficient and 
trouble-free operation.

Remove the air filter from the return air 
grille.

Remove dust from the air filter by using 
vacuum cleaner or, if it is very dirty, 
wash it with soap and wipe it dry 
before reinstalling it.

Remove the return air grille.

For plastic return grilles, no screw          
is used. Start removing the return grille 
by pulling the bottommost part of the 
grille.

WARNING:  Ensure that the power supply is switched off    

before commencing maintenance work.

1

2

3

Slide the air filter back into the return air 
grille.

Re-mount the return air grilles.

For plastics grilles, re-install the return 
air grille from top to bottom.

3

2

1

    KFM-36CHW / KFM-60CHWA

    KFM-36CHW / KFM-60CHWA

Cleaning The Unit

    

Clean the air conditioner with a 

     damp cloth and wipe it dry.
     Do not use water above 40

o

C for

     cleaning, as this will cause discolo-
     ration and deformation.
     Remove dust from the louver area 
     with your vacuum cleaner’s thin 
     nozzle.
     Do not splash directly with  water to 
     the body of the unit, as this may 
     cause a short circuit.
     Do not use thinner, benzene,
     abrasive powder, nor hot water to
     clean the unit.

5. CLEANING THE UNIT

Not to be Operated for a Long Period of Time

     

When the air conditioner is not going to be used for a long period

 of time, switch off the power from the circuit breaker.

Before Putting The System Back To Operation

    

Turn on the main power to the system at the outdoor unit.

     Run the unit in fan mode for a while to clear the air flow before you operate 
     it in another mode.

Tips on Using the Air Conditioner

After a Power Failure

     

Auto-restart function and non-volatile memory will automatically turn ON the unit

and return it to its previous setting. 

   

Clean the filter every other week for higher efficiency.

    Use curtains or blinds to prevent heat gain from the sunlight to the room.
    Doing so will help reduce electric consumption.
    Close all windows and doors when operating the unit so that there is no 
    leakage of conditioned air outside the room.
    Do not locate a heater or any other heat source near the unit. The heat 
    may deform plastic parts.

THE FOLLOWING ARE JUST NORMAL CONDITIONS FOR THE UNIT:

 

The unit does not operate upon 

restart.

If you restart the unit within 3 minutes after turning it

OFF, or change the mode during operation, a 
protective device will work to shut OFF the 
valve for 3 minutes.  Cooling will resume

automatically after the 3-minute delay.

Low Noise.

A soft, swishing noise can be heard during operation or 

immediately after the unit is turned OFF.  This is the 

sound of the circulating refrigerant.

 

Condensate water or water droplets 
present on the air outlet.

In COOL mode, condensate water can sometimes be  

seen forming on the air outlet due to the  

differences in temperature between the room air 
and the outlet air.

 

KOPPEL,  INC.,  warrants  to  the  purchaser  of  this  product  that  it  will  furnish  labor  and/or 
replacement  part  or  at  its  option,  repair  any  part  thereof  which  proves  upon  inspection  by 
KOPPEL, INC. or its authorized service company, to have been defective within one (1) year 
from the date of original purchase, if it was used thereafter solely within the Republic of the 
Philippines,  in  accordance  with  the  terms  of  this  warranty  through  the  KOPPEL,  INC. 
Service Department or any of its authorized service company.

This warranty  is non-transferable and does not apply to damage(s) arising from accident,   
improper  use  or  abuse,  force  majeure  such  as  typhoons,  floods,  lightning,  earthquakes 
among  others,  from  use  with  voltages  beyond  THE  ALLOWABLE  VOLTAGE  RANGE  OF 
207  TO  253  VOLTS,  or  from  failure  to  follow  operating  instructions  provided.  If  the  serial 
number  of  the  unit  is  removed,  obliterated  or  defaced,  or  if  the  unit  is  faultily  installed, 
tampered with or altered by anyone other than a duly authorized service personnel, service 
dealer or accredited installer of KOPPEL, INC., this warranty is considered null and void.

KOPPEL, INC. is not  responsible and will not be held liable in contract or in tort (including 
strict liability and negligence) for any special, indirect or consequential damages, including 
but  not  limited  to  damage  to  structure  or  contents,  or  injury  to  persons  by  reason  of  the 
installation, use or failure of any KOPPEL, INC. products. 

 

UNIT MODEL

 : ______________________________

 

SERIAL NUMBER

 :____________________________

 

PRODUCT WARRANTY CERTIFICATE

 

WARRANTY REGISTRATION FORM

IMPORTANT !

   

 In order not to void this warranty

 please fill up and detach this 

Warranty Registration Form and, within ten (10) days from date of receipt 
of equipment, 

mail 

 to Koppel, Inc. or send by 

fax

 to No. (02) 823-6999 . 

Also you can visit 

www.koppel.ph 

 

 

UNIT MODEL : ___________________________________________________

 

SERIAL NUMBER :________________________________________________

 

OWNER’S NAME : ____________________  TEL NO.:___________________

 

ADDRESS :  _____________________________________________________

 

DEALER’S NAME :  _______________________________________________

 

DATE PURCHASED :  _____________________________________________

 

INSTALLER’S NAME :

  

____________________________________________

(OWNER’S COPY)

Manufacturer reserves the right to discontinue, or change at any time, specification or designs

 without notice and without incurring any obligation.

PN: F30052

Rev. 00

6. TROUBLESHOOTING

PROBLEM

 

CAUSES

 

No operation

.

 

Check to see if the power supply switch is off.

 

Check to see if you have a power failure.

 

Check to see if the timer is in operation.

 

Air conditioner runs but does not
cool.

 

Check whether the room temperature is correct.

 

Check whether the sunlight is directly shining into the 
room.  If yes, use curtains or blinds to prevent heat 

gain to the room.
Check whether the door and the window are opened.
Ensure that no heating appliances have been placed 
near the air conditioner.

 

Check for obstructions in the air inlet and outlet. 

Check the air filter for dirt.

 

Call for service if the room does not cool after unit is
running for more than a reasonable cooling time.

 

Control pad is not working

.  

 

Call for service.

 

 

 

The drain hose on the outdoor unit

 

is cracked or broken.

 

Call for service

.  

There’s a strange noise coming

 

from the unit.

 

Call for service.

 

Water leaking from the indoor unit.

Call for service

.  

.