                                                                                                                         Page 

                   I.                      Introduction                                                                  2 

                  II.                      Incoming Inspection                                                    3 

                 III.                      Product Handling                                                         3 

                 IV.                      Product Identification and Nameplate                         4 

                  V.                      Principles of Operation                                                5 

                 VI.                      Pre-Installation Testing                                                6 

                VII.                      Specific Model Data                                               7 - 9 

                                                Mounting 

                                                Drawings and Dimensions 

                                                Technical Data 

                                                Major Component Replacements 

               VIII.                      Maintenance                                                       10 - 11 

                 IX.                      Trouble Shooting                                                        12 

                  X.                      Warranty                                                                    13 

 

NOTE:

 Wiring Schematics are available on the specific model page of the Kooltronic website.

 

 

I. Introduction

 

 

Kooltronic Air Conditioners are designed to provide a cool, dehumidified environment for 
your electronic components. There are models to fit virtually all sizes and shapes of 
electronic enclosures, in capacities ranging from 1,000 to 30,000 BTU/H. Our 
"closed-loop" design also ensures that your components will not be exposed to hot, dirty 
operating conditions. 
 
This Manual provides you with the necessary general information for properly installing 
and operating standard Kooltronic Air Conditioners. Technical data and mounting 
instructions are presented on pages 7 through 9. 

Summary of Contents for L17A3573

Page 1: ...AUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 F...

Page 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Page 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Page 4: ...ect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MO...

Page 5: ...ure accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the evaporator c...

Page 6: ...be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and co...

Page 7: ...TAB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and into the M TAB To avoid misalignment of parts do not tighten any of the scre...

Page 8: ...8 Drawings and Dimensions NP33 SERIES Other drain outlets are available contact KOOLTRONIC Dimensions inches are for reference only and are subject to change...

Page 9: ...12 8 90 K2A4C4NP33L 4000 120 50 230 200 60 50 5 5 90 K2A4C4NP33L5 4000 120 50 230 50 5 8 90 KA4C5NP33L 5000 125 50 115 100 60 50 12 8 90 KA4C5NP33L56 5000 125 50 115 50 60 12 8 90 K2A3C5NP33L 5000 125...

Page 10: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Page 11: ...pass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect r...

Page 12: ...Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Ap...

Page 13: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...