KOOLTRONIC, INC. 30 Pennington-Hopewell Road Pennington, NJ 08534
609 • 466-3400 FAX: 609 • 466-1114
kooltronic.com
Additional Information on this
air conditioner can be found by
visiting kooltronic.com and
searching for the model
number, or use the Technical
Documents QR code below.
V. Warranty
Kooltronic products are warranted to be free of defects in workmanship, materials and components. The following warranty periods apply from date of shipment:
•
Air moving devices/components and hermetic system components: 1 year
•
Spare parts, except filters: 90 days
The warranty applies when the equipment is operated under the following conditions:
•
Ambient temperature not in excess of 125°F (52°C) in normal atmosphere or as stated on product nameplate
•
Voltage variation no greater than ±10% from nameplate rating
•
Frequency variation no greater than ±3Hz from nameplate rating
•
Maximum cooling load no higher than air conditioner nameplate rating
•
Waiting five minutes before restarting air conditioner after intentional or accidental shutoff
•
Compliance to all other installation, maintenance and operating instructions
The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local electrical and safety codes, as well as the National Electric Code
(NEC) and OSHA
KOOLTRONIC cannot assume responsibility for misapplication of its products or the erroneous selection of an inappropriate product by a non-authorized KOOLTRONIC
representative. Our applications engineers will gladly assist in the selection of the proper product, provided all required details of the application are furnished.
KOOLTRONIC assumes no liability beyond the repair or replacement of its own product. This Warranty does not cover:
•
Labor or reimbursement of labor for evaluation, removal, installation, repair or cost of any warranted part, unless authorized in writing by Kooltronic
•
Use of equipment for other than its designed purpose or operating conditions
•
Operation in harsh, oily, corrosive or other abnormal environmental conditions, without the proper filtration, sealing, protective coatings and/or weather protection
•
Damage to hermetic system resulting from continuous operation with dirty or clogged air filters or improper or negligent maintenance
•
Use of refrigerant other than designated
•
Customer modification or abuse
•
Shipping damage or other accident (Claims for shipping damage are the responsibility of the customer. Timely claims must be filed by the customer with the
freight carrier)
•
Cracked or broken hermetic tubing, brazed joints or other internal damage caused by shipping damage or mishandling
•
Damage caused by shipping units attached to an enclosure
•
Any and all conditions resulting from noncompliance with the preceding operating conditions
•
Returned freight must be paid by customer
•
This Standard Warranty does not apply to custom products. Consult your Kooltronic representative for limitations
THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED,
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS KOOLTRONIC
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.
VI. Return Authorization (RA) Procedure
For information on our RA Procedure please visit the kooltronic.com homepage and look under Support.
Technical
Documents
You can register your warranty online by
going to our homepage at kooltronic.com,
under Support, or use the Warranty QR
code below.
Warranty
Registration
WARM AIR RETURN FROM
ENCLOSURE
COOL AIR OUTLET
TO ENCLOSURE
1
2
Dimensions, inches [mm], are for reference only and are subject to change.
EXTERNAL MOUNT GASKET PLACEMENT
INTERNAL MOUNT GASKET PLACEMENT
START AND END GASKET MATERIAL
HERE. USE ONE CONTINUOUS
PIECE OF GASKET. BEND GASKET
AROUND THE CORNERS, DO NOT
STRETCH THE MATERIAL.
INSTALL
MOUNTING BRACKET
START AND END GASKET
MATERIAL HERE.
USE ONE CONTINUOUS
PIECE OF GASKET.
BEND GASKET AROUND
THE CORNERS, DO NOT
STRETCH THE MATERIAL.
GASKET PLACEMENT
5.40
[137.1]
5.40
[137.1]
1.39
[35.3]
(6) .312 [7.9]
DIA. HOLES
9.70
[246.4]
1.72
[43.7]
6.54
[166.1]
9.65
[245.1]
7.60
[193.0]
1.17
[29.7]
7.60
[193.0]
1.13
[28.7]
1.19
[30.3]
5.60
[142.2]
5.60
[142.2]
21.32
[541.5]
0.30
[7.6]
17.54
[445.5]
1.63
[41.4]
5.60
[142.2]
5.60
[142.2]
.50
[12.8]
1.18
[30.0]
20.26
[514.5]
.24
[6.0]
2
1
1
2
EXTERNAL MOUNTING PLAN
INTERNAL MOUNTING PLAN
NOTE: THIS VIEW IS FROM INSIDE OF ENCLOSURE
5.59
[141.9]
5.59
[141.9]
1.21
[30.6]
(6) .312 [7.9]
DIA. HOLES
12.55
[318.9]
MOUNTING PLANS
MOUNTING PLATE DETAIL
MOUNTING
PLATE
WITH STUDS
MOUNTING PLATE IS NOT SYMMETRICAL.
INSTALL WITH LONGER SECTION AT THE
TOP AND SHORTER SECTION AT THE BOTTOM.
NOTE:
SHORTER
SECTION
AT BOTTOM
LONGER
SECTION
AT TOP