background image

7

VIII. Specific Model Data

Technical Data

KNP40F

115 VAC

50/60

.22/.22

18/17

60/69

14

158

5

K2NP40F

230 VAC

50/60

.10/.11

15/17

50/51

14

158

5

K6NP40F

12 VDC

-

0.4

4.8

52

14

140

5

K7NP40F

24 VDC

-

0.3

7.2

51

14

140

5

K8NP40F

48 VDC

-

<.1

-

57

14

158

5

Unit

Operating

Approximate

Frequency

Imput

Imput

Airflow

Temp. ºF

Weight

Model

Voltage

Hz

Amps

Watts

CFM

Min. Max.

(lbs.)

KNP60F

115 VAC

50/60

.27/.32

31/37

116/134

-40

158

6.5

K2NP60F

230 VAC

50/60

.12/.15

28/34

111/133

-40

158

6.5

K8NP60F

48 VDC

-

0.4

19.2

132

14

158

6.5

Unit

Operating

Approximate

Frequency

Imput

Imput

Airflow

Temp. ºF

Weight

Model

Voltage

Hz

Amps

Watts

CFM

Min. Max.

(lbs.)

KNP100F

115 VAC

50/60

.35/.38

36/38

141/172

-40

158

12.5

K2NP100F

230 VAC

50/60

.50/.45

64/62

151/188

-40

158

12.5

Unit

Operating

Approximate

Frequency

Imput

Imput

Airflow

Temp. ºF

Weight

Model

Voltage

Hz

Amps

Watts

CFM

Min. Max.

(lbs.)

Standard Features

Integrated Fan Guards
Integrated Sealing Gasket
Secure Mounting
Baked Powder Finish
UL/CSA Shielded Ball Bearing Motors
UL/CUL Listed
Washable, Reuseable Filter

Replacement Filters

Filter

Model

Part Number

KNP40F

531F

K2NP40F

531F

K6NP40F

531F

K7NP40F

531F

K8NP40F

531F

KNP60F

681F

K2NP60F

681F

K8NP60F

681F

KNP100F

1081F

K2NP100F

1081F

Optional Grille
Assemblies

Grille Assembly

Model

Part Number

KNP40F

KNPA40F

K2NP40F

KNPA40F

K6NP40F

KNPA40F

K7NP40F

KNPA40F

K8NP40F

KNPA40F

KNP60F

KNPA60F

K2NP60F

KNPA60F

K8NP60F

KNPA60F

KNP100F

KNPA100F

K2NP100F

KNPA100F

Summary of Contents for Advantage Sentry KNP100F

Page 1: ...14 www kooltronic com 900 057 05 11 21 CDR 20367 CAUTION BEFORE INSTALLING AND USING THIS FILTER FAN IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY Advantage Sentry Series NEMA 3R...

Page 2: ...nsions 6 VIII Specific Model Data 7 Technical Data Replacement Filters Optional Grille Assemblies IX Packing Procedure for Warranty Return 8 X Maintenance 8 XI Warranty 9 I Introduction This Manual pr...

Page 3: ...ooltronic Before servicing or cleaning this unit switch power off at the service panel and lock service panel to prevent power from being switched on accidentally If service panel cannot be locked sec...

Page 4: ...n identification nameplate This nameplate provides CAUTION Operate this unit only on the proper voltages and frequencies as noted on the nameplate Model Number Electrical Power Characteristics Serial...

Page 5: ...5...

Page 6: ...171 0 7 36 187 0 63 16 0 25 6 0 12 40 315 0 9 44 240 0 KNP100F 12 00 305 0 11 00 279 0 10 25 260 0 10 88 276 0 88 22 0 25 6 0 16 40 417 0 13 53 344 0 Model J K L M N P R S KNP40F 4 81 122 0 1 76 45 0...

Page 7: ...x lbs KNP100F 115 VAC 50 60 35 38 36 38 141 172 40 158 12 5 K2NP100F 230 VAC 50 60 50 45 64 62 151 188 40 158 12 5 Unit Operating Approximate Frequency Imput Imput Airflow Temp F Weight Model Voltage...

Page 8: ...eature an easily removable filter to facilitate necessary cleaning CAUTION 1 Remove the Torx tamper resistant screw at the bottom of the unit Remove the cover to expose the filter 2 Pull the filter do...

Page 9: ...received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a...

Reviews: