background image

must for patching measures or call for professionals.

7.4 Ensure the smoothness of drainpipes.

7.5 Frequently observe the operation of the product. In case of any abnormal noise, smell or

smog, cut off the power supply immediately and call for professionals for help. Do not restart the

product before trouble is cleared.

7.6 We will not be responsible for any accident incurred by failures of following the notices.

8. Frequent troubleshooting

Number

Troubles

Causes

Solutions

1

Strange noise under the
bottom shelf

Fan blade broken.

Power off and fix the blade.

2

Non-refrigerating in spite
of normal operation

1. Unit off.
2. Melting process.
3. Refrigerant leaking
4. Unit failure.

1. Power on.
2. Stop melting.
3. Patch the leak and refill
refrigerant.
4. Call for professionals.

3

Weak air from air curtain,
and

higher

cabinet

temperature

1. Evaporator blocked by frost.
2. Inside fan damaged.
3.Too

low

set

point

of

temperature controller.
4.Vent blocked by storage

1. Increase melting frequency.
2. Replace the fan.
3. Adjust the set point.
4. Remove the storage.

4

Normal air curtain, but
higher

cabinet

temperature

1. Insufficient refrigerant.
2.Too

high

set

point

of

temperature controllers.
3.Expansion value fails.
4.Thewind curtain disturbed by
strong air flow.
5. Ambient temperature or
humidity beyond standards.

1.Refill the refrigerant.
2.Adjust the set point for the
temperature controller.
3.Repair or replace the expansion
valve.
4. Removing the disturbing
factors.
5. Improve the conditions.

5

Melting water overflown

1.Heating pipe for melting water
damaged
2. Water-level controller failure.
3. Ambient temperature or
humidity beyond standards.

1. Replace the heating pipe.
2.Replace

the

water-level

controller.
3. Impove the conditions.

6

Normal air curtain, but

periodical fluctuation of
cabinet temperature

1.Condenser contaminated.
2. Poor venting of the unit.
3.Heatprotection of compressor
failure.
4.Expansion valve blocked by ice
5. Expansion valve failure.
6.

Temperature

controller

failure.

1. Clean the condenser.
2.

Improve

the

venting

conditions.
3. Replace the heat protection.
4. Replace the drying filter.
5. Replace the expansion valve.
6. Replace the temperature
controller.

Reviews: