IMPORTANT
: Installation must be
in compliance with the consumption
declaration. In order to ensure
adequate ventilation, the back panel
of the cabinet unit must be removed.
Installing the oven so that it rests on
two strips of wood is preferable. If
the oven rests on a continuous, flat
surface, there must be an aperture
of at least 1 ¾” x 22” (45 x 560mm).
(Refer to Figure 4.)
Figure 4
1.8”
(45 mm)
•
The panels of the adjacent cabinets must be made of heat-resistant material. In particular, cabinets with a
veneer exterior must be assembled with glues which can withstand temperatures of up to 212°F.
•
In compliance with current safety standards, contact with the electrical parts of the oven must not be
possible once it has been installed.
•
All parts, which ensure the safe operation of the appliance, must be removable only with the aid of a tool.
•
To fasten the oven to the cabinet, open the door of the oven and attach it by inserting the 4 wooden screws
into the 4 holes located on the perimeter of the frame.