Water drainage

Drained water can be collected and eliminated in 2 ways:
1, Remove the cover from the tank . Take out the tank and empty it
2. For continuous drainage take out tank, connect a pipeline inside the drain compartment and thread it through the

side panel of the unit to a suitable drain point (see diagram)

Notice about unit operation

1

When moving the unit, do not tilt over 45

°

to avoid any damaging of the compressor

The tilt angle of

compressor should be less than 5

°

when unit running. Ensure operation on a level surface.

2

the unit should be operated between 5

°

to 35

°

3

When dehumidifying, because of the heat resulted from the running compressor, the indoor

temperature will rise by 1

°

~3

°

Such a reaction should be considered as normal.

4

When the indoor temperature is below 5

°

and the ambient absolute humidity is quite low, it is

unnecessary to use the machine

5

Air inlet and air outlet should be at least 10cm away from the wall.

6

Try to keep the room closed to enhance the dehumidification effect.

7

Too much dirt to the filter affects dehumidificationand may even result in a malfunction. Thus if should

be cleaned once a month. If there is a great amount of powder in the air, the filter must be cleaned
once a week, or even every day. Pull the front panel out and clean the filter. If necessary, You may
lightly tap all over the surface of the filter., Use a vacuum cleaner to remove bigger pieces of dirt or
even wash the filter in warm clean water(

40% with some neutral detergents) and then dry it.