![Koolaire KD0172A Technician'S Handbook Download Page 57](http://html1.mh-extra.com/html/koolaire/kd0172a/kd0172a_technicians-handbook_1996839057.webp)
Part Number STH047 5/16
57
Ice Machine Cycles Into Harvest Before Water Contact
with the Ice Thickness Probe
Step 1
Bypass the freeze time lock-in feature by
moving the ON/OFF/WASH switch to OFF and back to ON.
Wait until the water starts to flow over the evaporator,
then monitor the harvest light.
Step 2
Disconnect the ice thickness probe from the
control board terminal.
ICE THICKNESS
PROBE
DISCONNECT
PROBE WIRE
BIN SWITCH
LIGHT
(GREEN)
HARVEST LIGHT
(RED)
SV1592J_2
Step 2 Disconnect probe from control board terminal.
Monitoring Harvest Light
Correction
The harvest light stays off and
the ice machine remains in the
freeze sequence.
The ice thickness probe is
causing the malfunction. Verify
that the ice thickness probe is
adjusted correctly.
The harvest light comes on,
and 6-10 seconds later, the ice
machine cycles from freeze to
harvest.
The control board is causing
the malfunction.