To reset the remote-controlled SMLD damper, proceed as shown in the following diagrams.

SMLD smoke evacuation damper

Mounting instructions

Control key

Close the slats manually, using the key provided with the damper

MAINTENANCE AND WARRANTY INSTRUCTIONS

No maintenance in particular.

Perform at least one operational test per year.

KOOLAIR shall be released from its liability in the event that the assembly, installation and electrical 

connections are not performed as set forth in this technical manual. In this case, the warranty is not 

ensured.

Pushbutton housing

12

Summary of Contents for SMLD

Page 1: ...www koolair com SMLD Mounting instructions Smoke evacuation damper...

Page 2: ...g to product type 2 Damper drawing 4 Fire resistance as per EN 13501 4 4 Product code explanation 4 Dimensions and openings 4 Testing and certification 5 Installation and on site placement 6 Frame mou...

Page 3: ...control Safety options Built in level 1 open close manual control Standby position contact DCU Safety position contact FCU Operating mode With intrinsic power supply With intrinsic power supply Contr...

Page 4: ...ection Any Any Fire direction Any Any Type of mounting Wall recessed Attachment with or without frame Wall recessed Attachment with or without frame Protection grille With RPK protection grille With R...

Page 5: ...oduct labelling FIRE RESISTANCE AS PER EN 13501 4 EI 120 Ved i o S 1500 AA MULTI PRODUCT CODE EXPLANATION E Integrity 120 Resistance time in min i o Either side of fire 1500 Pressure level in pascals...

Page 6: ...de la chaleur Partie 8 Volets de d senfumage Organisme Certificateur LGAI Technological Center S A Campus UAB Ronda de la Font del Carmen s n E 08193 Bellaterra Barcelona T 34 93 567 20 00 F 34 93 567...

Page 7: ...IN DUCTS OTHER THAN THOSE TESTED The multi com partment smoke control dampers are used with ducts subject to tests as per EN 1366 8 as appropria te or constructed from materials with the same density...

Page 8: ...in the duct with the help of 4 screws supplied with the frame Drill a hole to pass the connections to the duct SMLD MOUNTING Mount the damper in the mounting frame the folding feet of the damper are...

Page 9: ...rom moisture Avoid deterioration Avoid contact with water Avoid damper body deformation during assembly and sealing Avoid damper blows and tilting during transport Grille x4 Screws ACCESSORIES The use...

Page 10: ...wo pole standby setting contact start position Note The micro contacts are shown in their working position closed damper slats DC contact actuated and FC contact free Remote controlled version The rem...

Page 11: ...l Power Left Right Standby position contacts DCB Safety position contacts FCB Motor Standby position contacts DCU Safety position contacts FCU Remote controlled version motor Right Standby position co...

Page 12: ...on of sealing products and handled with care During commissioning of the installation clean all dust and grime on the assembly to prevent risks of slat deterioration The electromagnetic coil is an ext...

Page 13: ...g the key provided with the damper MAINTENANCE AND WARRANTY INSTRUCTIONS No maintenance in particular Perform at least one operational test per year KOOLAIR shall be released from its liability in the...

Page 14: ...THIS CATALOGUE IS COPYRIGHTED Partial or full reproduction of its content is strictly prohibited without express written authorisation from KOOLAIR S A CEN MISMLD 1115 00 13...

Page 15: ...2 La Fuensanta 28936 M stoles MADRID Tel 34 91 645 00 33 Fax 34 91 645 69 62 e mail comercial comercial koolair com e mail Koolair info koolair com Koolair S A reserves the right to change publisher...

Reviews: