background image

 

 
BAKL6U022AA 

Edition: 28.02.2017

 

Page: 9/9 

 

6. 

Waste disposal in accordance with legal provisions 

After the phase of use the last proprietor is responsible for the adequate waste manage-
ment. The environmental regulations in the exporting country must be observed.

 

The following list contains the most important regulating literature, valid for the 

Federal Rep. of 

Germany

  Resolution for dangerous substances 

  Law for waste circulation (KRW/AfgG)) 

  Resolution for the proofs of utilization and 

removal 

  Criminal Code (StGB) 28th section „crimi-

nal acts against the environment” §326 - 
Environment jeopardizing waste manage-
ment 

  Law of chemicals § 27 - penal prescriptions 

  Resolution for used oil 

  Law of water balance 

  Resolution for the waste management of old 

cars and the adaptation of road prescrip-
tions 

  Resolution (EC) No. 2037/2000 of the Euro-

pean Parliament and of the Council for ma-
terials that affect the ozone layer 

  Resolution to prohibit certain ozone destroy-

ing halogen hydrocarbons. 

The used refrigerant endangers the environment. When dealing with refrigerants the existing pre-
scriptions and regulations are to be followed.

 Only qualified staff is allowed to

 

carry out these 

works! 

Water endangering substances - acc. to §§19g-19l - are solid, liquid, and gaseous substances. 
e.g.: mineral and tar oils (cooling oils), halogen containing organic combinations (refrigerants). 
 

  

Source of supply: 

Bundesanzeiger 

Beuth Verlag 

dtv (Deutscher Taschenbuch Verlag

 

 
 

7. 

History of modification 

Version  Date 

Name 

Remark 

File 

A00 

03.02.2010  B. Keßler  Source file 

BAKL6U022AA 

A01 

21.01.2014  B. Keßler  Added safety instructions (Foreword), Ma-

chinery Directive p.4 updated, updated risk of 
accidents Pkt.4 and item 5 mail address 

BAKL6U022AA 

A02 

03.11.2016  B. Keßler  Item 1.2 pressure switches deleted 

BAKL6U022AA 

A03 

28.02.2017  B. Keßler  Information on the operating instructions and 

technical data expanded with F-gas-
regulation 

BAKL6U022AA 

 

Summary of Contents for UL500

Page 1: ...chwalmstadt Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instructions for KONVEKTA Air Conditioning units UL500 UL700 UL800 with Wabco control system R134a 24 Volt DC ID BBA KL6U022AA Version A03 ...

Page 2: ...ction of the keys 6 3 1 1 Flap for windshield floor 6 3 1 2 Desired value of front box temperature 6 3 1 3 Blower speed 6 3 1 4 Smog 6 3 1 5 Heater passenger s compartment 7 3 1 6 Additional heater 7 3 1 7 Reheat 7 3 1 8 Driver s seat air conditioning 7 3 1 9 General 7 4 Wartung 7 4 1 Troubleshooting 8 5 Warranty Conditions 8 6 Waste disposal in accordance with legal provisions 9 7 History of modi...

Page 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provi sions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any...

Page 4: ...t may differ in some parts of description In case your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without no tice Guarantee and liability conditions of KONVEKTA AG s genera...

Page 5: ... and aluminium components cannot be ruled out The cupper and aluminium components of the KONVEKTA systems are not suitable for such extreme application conditions We indicate emphatically that corrosion is not subject to warranties for defects KONVEKTA does not take over any warranties for defect neither for corrosion nor for consequential damage resulting there from nor for damages caused by clea...

Page 6: ...osition Air circulation is split up between floor and windshield Arrow up flap for windshield The whole air is lead to the windshield Symbol windshield defrost Water valve completely opened air to windshield max imal blower speed The conversion is realized via characteristic curves which also facilitate intermediate positions 3 1 2 Desired value of front box temperature The blowout temperature of ...

Page 7: ...nce works we refer to our maintenance instructions BWA KL6U022AA which have been written exclusively for maintenance personal Please arrange regular dates for maintenance works and services with a KONVEKTA service station as indicated in maintenance schedule bus no WP07050618 Only qualified staff is allowed to carry out these works For general instructions on repair and maintenance works please co...

Page 8: ... magnetic clutch compressor does not compress check high and low pressure replace com pressor if necessary excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil with compressed air excess pressure caused by high out side temperature run unit until pressure has stabilized leakage in a c unit lack of refrigerant check a c unit for leakages refill refriger...

Page 9: ...of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and gaseous s...

Reviews: