Operating Instruction 

for KONVEKTA 

Air Conditioning unit 

KL40T / KL45T / KL46T 

with control KS60 

 
Versions: 

 

12 / 24 Volt DC

 

 

Recirculated Air

 

 

Fresh Air

 

 

Heating

 

ID#: BBA-KL40T12AA 
Version: A05

 

 

Summary of Contents for KL40T/12V

Page 1: ...many 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA Air Conditioning unit KL40T KL45T KL46T with control KS60 Versions 12 24 Volt DC Recirculated Air Fresh Air Heating ID BBA KL40T12AA Version A05 ...

Page 2: ...of a c system 8 5 3 Adjustment of temperature 8 5 4 Recirc Air operation only in case of a c units with Rec air flaps option 8 5 5 REHEAT activate stop 8 5 6 Display of air duct temperature 8 5 7 Indicate outside temperature only in case of a c units with heating option 9 6 Maintenance Servicing 9 6 1 Oil change Compressor type KVX 9 6 2 Return air grid 9 6 3 Condenser coil 9 6 4 Troubleshooting 1...

Page 3: ...increases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any ...

Page 4: ... In case your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged...

Page 5: ...rd fans and or blowers 1 1 Compressors Important To avoid leakages at the shaft seal of the compressor The compressor should be started every 4 weeks for approx 15 minutes This also applies when the vehicle is not into operation for a longer period or when the air conditioning unit is not used Compressor type depending on scope of delivery see identification plate at compressor Compressor Type KVX...

Page 6: ...e environmental conditions i e air containing salt phosphate or ammoniac extremely a corrosion of the cupper and aluminium components can not be ruled out The cupper and aluminium components of the KONVEKTA systems are not suitable for such extreme application conditions We indicate emphati cally that corrosion is not subject to warranties for defects KONVEKTA does not take over any war ranties fo...

Page 7: ...all displays against irritating sunglare and any other optical disturbances Please note that the control panel keys have not been designed for heavy stressing Excessive or fast pressing of the keys for adjusting the set temperature does not accelerate the cooling down process It possibly damages the control panel and so affects the general perfor mance of the air conditioning unit 5 1 Operation pa...

Page 8: ...o interior room of the vehicle see 4 Start of the recirculated air operation Press key S6 the LED display will light up This position should not be adjusted very long If windows are misting up return air operation should be switched off If key S6 is pressed again the return air flap will be reactivated and fresh air operation restarted The LED display will go out Automatic In case of a temperature...

Page 9: ...r operational reliability We recommend having all works and modifications carried out at an authorized KONVEKTA Service Station Before carrying out any maintenance works at your air conditioning unit carefully read the KONVKETA safety provisions TD00052A in order to avoid any dangers and accidents On our website www konvekta com in category service you will find a survey of contact details of all ...

Page 10: ...ck fuses at switchboard clean condenser coil with compressed air LED flashes up excess pressure caused by high outside temperature run unit until pressure has stabilized leakage in a c unit lack of refriger ant check a c unit for leakages refill refrigerant low pressure dryer clogged replace dryer low pressure screen of expansion valve clogged clean screen replace dryer compressor does not compres...

Page 11: ...als that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out these works Water endangering substances acc to 19g 19l are solid liquid and gaseous substances e g mineral and ...