Kontron IP Network Server NSC2U
December 2009
Product Guide, rev. 1.4
57
Optional Component Installations—NSC2U Server
4.4
Installing Intel
®
Remote Management Modules
To install the GCM module and Remote Management Module (RMM), you must first
remove the chassis top cover, the processor air duct, and PCI riser card assembly.
4.4.1
Installing the GCM Module
1. Remove the filler panel from the rear panel of the chassis by squeezing the side
edges and pulling it out. (
)
2. Snap the two standoffs into the server board. (
, “C”)
3. Attach the module to the server board using the connector. (“D”)
4. If this is the last task you are performing, replace the riser card assembly, the
processor air duct, and the top cover of the chassis. Reconnect all the external
devices and plug in the power cord(s).
For information about mounting the server in a rack, see
the Server into a Rack” on page 48
.
4.4.2
Installing the RMM Module
1. Remove the PCI riser card assembly to access the RMM site on the T5000PAL
server board. (For instructions, see
.)
2. Snap the standoff into the T5000PAL server board. (
, “A”)
3. Fasten the RMM module to the server board site using the connector (“B”) and the
standoff hole.
Figure 39.
Removing the GCM Port Filler Panel
TS000548
A