![Kontron MSP8020 Series User Manual Download Page 28](http://html1.mh-extra.com/html/kontron/msp8020-series/msp8020-series_user-manual_1996308028.webp)
MSP8020 Series User Guide Rev. 1.1
www.kontron.com
// 28
ID
Hex ID
Sensor Name
Sensor Type Code
Reading Type Code
Description
24
0x18
IPMI Info-1
C0h (OEM Firmware Info)
70h (OEM Kontron Internal
Diagnostic)
Internal Management Controller
firmware diagnostic
25
0x19
IPMI Info-2
C0h (OEM Firmware Info)
71h (OEM Kontron Internal
Diagnostic)
Internal Management Controller
firmware diagnostic
26
0x1A
POST Value
C6h (OEM POST Value)
6Fh (Sensor Specific)
Show current postcode value
(No event generated)
27
0x1B
Health Status
24h (Platform Alert)
7Fh
(OEM Health Status)
General health status
(Aggregation of critical sensors)
28
0x1C
EventRcv ComLost
1Bh Cable/Interconnect
03h (Digital Discrete)
Communication loss with the event receiver (ShMC)
29
0x1D
BMC Reboot
24h (Platform Alert)
03h (Digital Discrete)
BMC Reboot detection
30
0x1E
BMC Storage Err
28h (Management
Subsystem Health)
6Fh (Sensor Specific)
Management sub-system health
(non volatile memory error)
31
0x1F
BMC SEL State
10h (Event Logging Disable)
6Fh (Sensor Specific)
Specify the status of the SEL
(Cleared/Almost full/Full)
32
0x20
SEL Time Set
12h (System)
6Fh (Sensor Specific)
Specify when SEL time change
33
0x21
Jumper Status
D3h (OEM Jumper Status)
6Fh (Sensor Specific)
Reflects on-board jumper presence
34
0x22
Thermal Error
0Ah (Cooling Device)
03h (Digital Discrete)
Cooling problem