Kontron MSP8020 Series User Manual Download Page 1

 

USER GUIDE 

 

 

MSP8020 Series 

Doc. Rev. 1.1 

 

 

 

Summary of Contents for MSP8020 Series

Page 1: ...USER GUIDE MSP8020 Series Doc Rev 1 1...

Page 2: ...table for the specified use without further testing or modification Kontron expressly informs the user that this manual only contains a general description of processes and instructions which may not...

Page 3: ...ion KVM hint SWMI update Sensors lists add 2016 May 26 Customer Service Visit our site at www kontron com Customer Comments If you have any difficulties using this user s guide discover an error or ju...

Page 4: ...precautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the High Voltage Safety Instructions portion below in th...

Page 5: ...Node Key Components 12 1 5 Node Features 13 1 6 Node Module LEDs and Buttons 14 1 7 Network Interfacing 15 1 8 Management Interfacing 16 2 Extracting and Inserting a Node Module 19 2 1 Extracting a No...

Page 6: ...List of Acronyms BMC Base Management Controller CLI Command Line Interface ECC Error Checking and Correction ETSI European Telecommunications Standards Institute FRU Field Replaceable Unit HPM PICMG...

Page 7: ...cement of any part assembly or sub assembly at their own discretion or to refund the original cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership...

Page 8: ...MSP802x reference through this guide refers to any variants of this Node Series as describe per Table 2 node key components unless specified otherwise MS29xx reference through this guide refers to any...

Page 9: ...e 2 MSP802x in rear of chassis For information on other SYMKLOUD MS29xx components refer to the specific component s user manual To ensure you have the latest document version or to consult other SYMK...

Page 10: ...MSP8020 Series User Guide Rev 1 1 www kontron com 10 1 2 Block Diagram Figure 3 MSP802x block diagram For a block diagram of the entire MS29xx system refer to the SYMKLOUD MS29xx Platform User s Guide...

Page 11: ...KT Controller rev 04 00 19 0 153a Ethernet controller Intel Corporation Ethernet Connection I217 LM 00 1a 0 8c2d USB controller Intel Corporation Lynx Point USB Enhanced Host Controller No 2 00 1d 0 8...

Page 12: ...2 DIMM slots for up to 16 GB DDR3 supports ULP VLP unbuffered 1 35V DDR3 with ECC MSP8022 E3 1278L v4 support 16G dimm for 32GB total cpu Network connections 1 Intel 1GbE controller I210 IS 1 chipset...

Page 13: ...f sensors Validated OS Ubuntu Server 64 bit long term support release 12 04 Windows 7 64 bit SP1 CentOS Linux 64 bit release 6 4 For a list of current validated OS refer to the product s THOL Hot swap...

Page 14: ...st one CPU engine OFF ON ON not healthy OFF healthy Payload power OFF OR Both payloads are OFF ON OFF ON not healthy OFF healthy Both payloads are OFF ON OFF ON not healthy OFF healthy Power button St...

Page 15: ...connects to hub 1 Figure 5 The KVM functionality of each CPU is on each one s respective fabric port Therefore if the connection to a hub is lost the KVM functionality of a CPU will be lost Each CPU s...

Page 16: ...Guide The MSP802x node has a KVM functionality that gives users remote access to the CPU engines The remote console is the redirected screen keyboard and mouse of the remote host system Through media...

Page 17: ...d Example of an SOL connection to the node CPU serial console OS 1 Connect to the management port with a cable or via a network 2 Establish an SOL connection using ipmitool From a PC ipmitool H node B...

Page 18: ...rl gg use the Ctrl g ASCII control code 2 times in a row Example of a serial connection to the node CPU serial console OS 1 Connect a PC to the active hub s console port 2 Establish a connection using...

Page 19: ...rocedures 1 Press the power button of the node to be extracted The power button should be configured in the operating system so that it performs a clean shutdown when pressed 2 The ID LED of the node...

Page 20: ...BMC initialization the power LED of the processor node module becomes steady green the processor node module is powered on and ready to use 2 3 System Behavior upon Hot Swap The system is electrically...

Page 21: ...t enter the number of the switch and that this number can be between 1 and 5 The symbol indicates a choice between two or more alternatives e g x y z reads x or y or z Elements in black bold are selec...

Page 22: ...ipmitool ipmitool set targetaddr node BMC ipmi address ipmitool power reset both cpu From an IOL remote PC ipmitool H node BMC ip address U admin P admin power reset OR ipmitool H ShMC ip address U ad...

Page 23: ...se the or key to move the boot device up or down Select the Save Exit tab Select Save Changes and Reset You can boot from a LAN or from onboard storage The default Boot Priority Order is as follows SA...

Page 24: ...RT UPGRADE To update all updatable firmware of the node ipmitool H node BMC ip address U admin P admin hpm upgrade HPM file all activate API calls available to update a node Notes This operation must...

Page 25: ...MSP8020 Series User Guide Rev 1 1 www kontron com 25 PAGE LEFT BLANK INTENTIONALY...

Page 26: ...Sensor 2 0x02 FRU2 Hot Swap F0h ATCA HotSwap Sensor 6Fh Sensor Specific ATCA HotSwap Sensor 3 0x03 FRU0 Reconfig 12h System Event 6Fh Sensor Specific Sensor population change on carrier 4 0x04 Temp Br...

Page 27: ...board 3 3V suspend power supply 16 0x10 Vcc 1 5V SUS 02h Voltage 01h Threshold Based Voltage on board 1 5V suspend power supply 17 0x11 Vcc 1 2V SUS 02h Voltage 01h Threshold Based Voltage on board 1...

Page 28: ...health status Aggregation of critical sensors 28 0x1C EventRcv ComLost 1Bh Cable Interconnect 03h Digital Discrete Communication loss with the event receiver ShMC 29 0x1D BMC Reboot 24h Platform Aler...

Page 29: ...sub system health non volatile memory error 4 0x04 Bx IPMI Watchdog 23h Watchdog 6Fh Sensor Specific IPMI Watchdog payload watchdog 5 0x05 Bx CPU Reset CFh Board Reset 03h Digital Discrete Board rese...

Page 30: ...PWROK Capt 2 08h Power Supply 03h Digital Discrete Latched power rail status 16 0x10 Bx CPU Status 07h Processor 6Fh Sensor Specific Processor 0 Status 17 0x11 Bx ACPI State 22h System ACPI Power Stat...

Page 31: ...on Power Good 08h Standard IPMI Power Supply 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 1 05V_M 0 75V_SUS 1 25V_SUS 1 5V_SUS 3 3V_SUS Combined 3 3V_SUS 1 5V_SUS 1 25V_SUS 0 75V_SU...

Page 32: ...Warm reset 01h Cold reset 02h Forced Cold Warm reset reverted to Cold 03h Soft reset Software jump 04h Hard Reset 05h Forced Hard Warm reset reverted to Hard Event Data 3 Reset Source 00h IPMI Watchd...

Page 33: ...tical fault Event Data 3 If the sensor is an aggregation sensor then event data 2 is used to return the ID of the first sensor from the aggregation that caused the fault Sensor Aggregation List FRU0 I...

Page 34: ...hem to focus on their core competencies by offering a complete and integrated portfolio of hardware software and services designed to help them make the most of their applications With a significant p...