4.4.1 CRT Connector (CRT)
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
6 GND
PWR
-
-
/75R
*
A0
RED 1
11
NC
-
-
-
7 GND
PWR
-
-
/75R
*
A0
GREEN 2
12
DDCDAT
IO
TBD
6K81
2
8 GND
PWR
-
-
/75R
*
A0
BLUE 3
13
HSYNC
O
TBD
9
5V
PWR
-
-
1
-
-
-
NC 4
14
VSYNC
O
TBD
10
GND
PWR
-
-
-
-
PWR
GND 5
15
DDCCLK
IO
TBD
6K81
2
Note 1:
The 5V supply in the CRT connector is fused by a 1.1A reset-able fuse.
Note 2:
Pull-up to +5V.
Signal Description - CRT Connector:
Signal
Description
HSYNC
CRT horizontal synchronization output.
VSYNC
CRT vertical synchronization output.
DDCCLK
Display Data Channel Clock. Used as clock signal to/from monitors with DDC interface.
DDCDAT
Display Data Channel Data. Used as data signal to/from monitors with DDC interface.
RED
Analog output carrying the red color signal to the CRT. For 75 Ohm cable impedance.
GREEN
Analog output carrying the green color signal to the CRT. For 75 Ohm cable impedance.
BLUE
Analog output carrying the blue color signal to the CRT. For 75 Ohm cable impedance.
DIG-GND
Ground reference for HSYNC and VSYNC.
ANA-GND
Ground reference for RED, GREEN, and BLUE.