10. Maintenance and Prevention
KISS 4U V2 – User's Guide (Version 1.01)
10.
Maintenance and Prevention
Equipment from Kontron Europe requires only minimum servicing and maintenance for problem-free operation.
For light soiling, clean the KISS 4U V2 with a dry cloth.
Stubborn dirt should be removed using a mild detergent and a soft cloth.
Clean the filter mat regularly (see chapter 10.1 “Cleaning the Filter Mat”).
10.1.
Cleaning the Filter Mat
The filter mat is inserted in the filter mat holder at the front side of the fan slide-in module (Fig. 37, pos. 4). The soiling of
the filter mat is caused by the pollution of the operating environment. A heavily soiled filter mat can cause excessive
heating of the device. For this reason we recommend to clean the filter mat as often as necessary. The filter mat can be
changed during operation of the system.
Fig. 37: Detail: Filter mat holder on the front side of the KISS 4U V2 platform
To replace the filter mat, proceed as follows:
1.
Open the front access panel (Fig. 37, pos. 5).
2.
Loosen the knurled screw that secures the filter mat holder to the fan slide-in module (Fig. 37, pos. 4 and Fig. 39,
pos. 5).
3.
Pull the filter mat holder out of the positioning holes (Fig. 38, pos. 3) into the marked direction (see Fig. 37) and lift
it off.
4.
Remove the soiled filter mat (Fig. 37, pos. 2 and Fig. 41).
5.
Clean the filter mat as follows:
Rinse in water (up to approx. 40°C; possibly with the addition of a standard mild detergent).
It is also possible to beat the filter pad, to vacuum it or blow it with compressed air.
For dirt that contains grease/oil, the filter pad should be rinsed with warm water with the addition of a degreaser.
Filter pads should not be cleaned with powerful water jets or wrung out.
1
Front side of the KISS 4U V2 platform
2
Filter mat
3
Filter mat holder with knurled screw
4
Fan slide-in module
5
Front access panel
1
2
3
5
4
www.kontron.com
37