7. Assembly, Disassembly
KISS 4U KTC5520 – User's Guide (Version 1.01)
7.3.
Fan Slide-in Module and Temperature Sensors
The three system fans (Fig. 24, pos. 3) are integrated in a user-friendly, replaceable fan slide-in module (hot-swap)
(Fig. 11, pos. 9 and Fig. 38, pos. 1). The fan slide-in module is mounted in a fan compartment on the front side of the
system (Fig. 39, pos. 5).
The system fans are temperature controlled via the temperature sensors installed in the KISS 4U KTC5520 platform. Thus,
a reliable air circulation for optimal active cooling of the platform is guaranteed.
The temperature conditions of the system (depending on the environmental temperature and the system load) are
detected by three temperature sensors. Two temperature sensors are located in the rear part (near the ventilation
openings) and the second sensor is placed sideways in the mid part of the KISS 4U KTC5520 platform.
1
2
6
2
1
3
5
4
1
Fig. 23: Side view of the fan
slide-in module
Fig. 24: Side with connector of the fan slide-in module
Legend for
and
1
Fan slide-in module with two knurled screws
2
Connector for fan control
3
3x fans (temperature controlled
independently from each other)
4
Bracket of the fan slide-in module
5
Case of the fan slide-in module
6
Mounted filter mat holder with knurled
screws
The operation of the KISS 4U KTC5520 platform is permitted only with a functional fan slide-in module!
Defective components may only be replaced by Kontron original spare parts:
“fan slide-in module”, part number: 1036-5056
Important Instructions!
The fan slide-in module can be replaced during operation. This should only be carried out by qualified
personnel aware of the associated dangers (see chapter 9.2 “Replacing the System Fans”).
24