3 Specifications
Kontron User's Guide ETX CD
16
3.4
Environmental Specifications
3.4.1
Temperature
Operating: (with Kontron Embedded Modules heat-spreader plate assembly):
®
Ambient temperature: 0°C to 60°C
®
Maximum heatspreader-plate temperature: 0°C tp 60°C (*)
Non-operating:
®
-30°C to 85°C
See the Thermal Management chapter for additional information.
Note: *The maximum operating temperature with the heatspreader plate is the maximum measurable temperature
on any spot on the heatspreader’s surface. You must maintain the temperature according to the above
specification.
Operating (without Kontron Embedded Modules heat-spreader plate assembly):
®
Maximum operating temperature: 0°C to 60°C (**)
Non operating:
®
-30° to +85°C
See the Thermal Management chapter for additional information.
Note: **The maximum operating temperature is the maximum measurable temperature on any spot on a module’s
surface. You must maintain the temperature according to the above specification.
3.4.2
Humidity
®
Operating: 10% to 90% (non condensing)
®
Non operating: 5% to 95% (non condensing)
3.5
MTBF
The following MTBF (Mean Time Between Failure) values were calculated using a combination of
manufacturer’s test data, if the data was available, and a Bellcore calculation for the remaining parts.
The Bellcore calculation used is “Method 1 Case 1”. In that particular method the components are
assumed to be operating at a 50 % stress level in a 40° C ambient environment and the system is
assumed to have not been burned in. Manufacturer’s data has been used wherever possible. The
manufacturer’s data, when used, is specified at 50° C, so in that sense the following results are slightly
conservative. The MTBF values shown below are for a 40° C in an office or telecommunications
environment. Higher temperatures and other environmental stresses (extreme altitude, vibration, salt
water exposure, etc.) lower MTBF values.
®
System MTBF (hours) :
109418
Summary of Contents for ETX CD
Page 1: ... Kontron User s Guide ETX CD Document Revision 1 0 All not approved entries are marked ...
Page 2: ...This page intentionally left blank ...
Page 39: ...4 ETX connectors Kontron User s Guide ETX CD 39 44 Reserved nc 45 Reserved nc ...
Page 57: ...10 BIOS Operation Kontron User s Guide ETX CD 57 10 3 BIOS Setup Menus 10 3 1 Info Screen ...
Page 60: ...10 BIOS Operation Kontron User s Guide ETX CD 60 10 3 3 Advanced ...
Page 76: ...10 BIOS Operation Kontron User s Guide ETX CD 76 Hardware Monitor ...