background image

D R A F T   —   F O R   I N 

T E R N A L   U S E   O N L Y

10

www.kontron.com

User Guide

CPS3105

2   Functional Description

2.1   Board Inter faces

2.1.1   Front Panel LED

The CPS3105 provides one Power Status LED on the front panel.

2.1.2   XMC Interface

The CPS3105 uses one x8 PCI Express 2.1 interface operating at 5.0 GT/s and compliant with the ANSI/
VITA 42.0 and ANSI/VITA 42.3 specifications. 

XMC modules are based on 3.3 V power along with variable power (VPWR) defined as either 5 V or 12 V
in the ANSI/VITA 42.0-200x XMC Switched Mezzanine Card Auxiliary Standard specification. On the
CPS3105, the VPWR is configured to 12 V.

Note:

XMC integrators should carefully review the power ratings, cooling capacity and airflow re-
quirements in the application prior to installation of an XMC module on the CPS3105.

2.1.3   CompactPCI Serial Interface

The CPS3105 provides a standard CompactPCI Serial interface compliant with the PICMG® CPCI-S.0 R 1.0
CompactPCI® Serial Specification. The interface is comprised of one CompactPCI Serial connector, P1.
The pin assignment of the P1 connector is defined in the PICMG® CPCI-S.0 R 1.0 CompactPCI® Serial
Specification.

Table 5: Power Status LED

LED

COLOR

STATE

FUNCTION

Pwr

green

Off

Power off

On

Power on

Table 6: Compatibility Identification Block acc. to ANSI/VITA 42.3

XMC Form Factor

Standard XMC.3

Connector Identifier

P15 (J2 on the CPS3105)

Protocol Identifier

PCIe

Signal Voltage Parameter

Standard

Keywords 1 - 3

8 Lane

Link 0

5.0Gb/s

Table 7: XMC Module Current

VOLTAGE

CONTINUOUS CURRENT

PEAK CURRENT

3.3 V / 3.3 V AUX

2.0 A

2.5 A

+12 V / VPWR (12 V)

2.5 A

3.0 A

-12 V

0.15 A

0.2 A

Summary of Contents for CPS3105

Page 1: ...D R A F T F O R I N T E R N A L U S E O N L Y The pulse of innovation User Guide CPS3105 Doc ID 1055 0548 Rev 1 0 Date July 3 2013...

Page 2: ...kontron com Disclaimer Copyright 2013 Kontron AG All rights reserved All data is for information purposes only and not guaranteed for legal purposes Information has been carefully checked and is beli...

Page 3: ...rd Diagrams 6 1 2 1 Functional Block Diagram 6 1 2 2 Front Panel 7 1 2 3 Board Layout 7 1 3 Technical Specification 8 1 4 Standards 8 1 5 Related Publications 9 2 Functional Description 10 2 1 Board I...

Page 4: ...tandards 8 3 Additional Standards for Boards Ordered with Ruggedized Service 9 4 Related Publications 9 5 Power Status LED 10 6 Compatibility Identification Block acc to ANSI VITA 42 3 10 7 XMC Module...

Page 5: ...any means disclosed to others or stored in any retrieval system or media without the prior written consent of Kontron or one of its authorized agents The information contained in this document is to t...

Page 6: ...rst it decouples and buffers the PCI Express signals and restores signal integrity Second it is able to convert one x4 PCI Express 3 0 data stream from the system side into one x8 PCI Express 2 1 data...

Page 7: ...com User Guide CPS3105 1 2 2 Front Panel Figure 2 4 HP CPS3105 Front Panel 1 2 3 Board Layout Figure 3 4 HP CPS3105 Board Layout Top View CPS3105 Pwr XMC Power Status LED Pwr green Power Status of the...

Page 8: ...ystem LED Front Panel LED Power Status LED Pwr green Power Status of the CPS3105 General Mechanical 3U 4 HP CompactPCI Serial compliant form factor Power Consumption approx 4 7 W without XMC module Po...

Page 9: ...ollowing publications contain information relating to this product Table 3 Additional Standards for Boards Ordered with Ruggedized Service TYPE ASPECT STANDARD REMARKS Environmental Vibration Sinusoid...

Page 10: ...irflow re quirements in the application prior to installation of an XMC module on the CPS3105 2 1 3 CompactPCI Serial Interface The CPS3105 provides a standard CompactPCI Serial interface compliant wi...

Page 11: ...ly discharged before touching the product with his her hands or tools This is most easily done by touching a metal part of your system housing Do not handle this product out of its protective enclosur...

Page 12: ...met When removing a board from the system particular attention must be paid to the components which may be hot such as heat sink etc To preclude damage or data loss when removing the CPS3105 ensure th...

Page 13: ...85386 Eching Munich Germany Tel 49 0 8165 77 777 Fax 49 0 8165 77 219 info kontron com North America 14118 Stowe Drive Poway CA 92064 7147 USA Tel 1 888 294 4558 Fax 1 858 677 0898 info us kontron co...

Reviews: