Installation
CP-RIO6-M
Page 3 - 4
ID 1031-2494, Rev. 2.0
P R E L I M I N A R Y
3.2
Initial Installation Procedures
The following procedures are applicable only for the initial installation of the CP-RIO6-M in a
system.
To perform an initial installation of both the CP-RIO6-M in a system, proceed as follows:
1. Ensure that the safety requirements indicated Chapter 3.1 are observed.
2. Ensure that the CP-RIO6-M is compatible with the CPU board and the backplane prior to
installation.
3. Ensure that the SATA devices are properly installed prior to installation.
4. Ensure that no power is applied to the system before proceeding.
5. Carefully insert the CP-RIO6-M into the slot designated by the application requirements
for the CP-RIO6-M until it makes contact with the backplane connectors.
6. Using both ejector handles, engage the CP-RIO6-M with the backplane. When the ejec-
tor handles are locked, the CP-RIO6-M is engaged.
7. Fasten the two front panel retaining screws.
8. Ensure that the CP-RIO6-M is properly secured.
The CP-RIO6-M is now ready for initial operation.
Warning!
Failure to comply with the instruction below may cause damage to the
CP-RIO6-M or result in improper system operation.
Warning!
When performing the next step,
DO NOT
push the CP-RIO6-M into the
backplane connectors. Use the ejector handles to seat the CP-RIO6-M into
the backplane connectors.