Kontron COM Express Extension Specification Download Page 14

4 Signal Description

 

Copyright © COM Express™ Extension  

 

Specification Rev 013 

14 

 

D61 

 

SD 

TMDS Clock + 

DPB_LANE3 

D62 

PEG_TX3- 

SDVOB_CLK- 

TMDS Clock - 

DPB_LANE3# 

D63 

RSVD 

RSVD 

RSVD 

RSVD 

D64 

RSVD 

RSVD 

RSVD 

RSVD 

D65 

 

SD 

TMDS DATA 5+ 

DPC_LANE0 

D66 

PEG_TX4- 

SDVOC_RED- 

TMDS DATA 5- 

DPC_LANE0# 

D67 

GND 

GND 

GND 

GND 

D68 

 

SD 

TMDS DATA 4+ 

DPC_LANE1 

D69 

PEG_TX5- 

SDVOC_GRE- 

TMDS DATA 4- 

DPC_LANE1# 

D70 

GND (FIXED) 

GND (FIXED) 

GND (FIXED) 

GND (FIXED) 

D71 

 

SD 

TMDS DATA 3+ 

DPC_LANE2 

D72 

PEG_TX6- 

SDVOC_BLU- 

TMDS DATA 3- 

DPC_LANE2# 

D73 

SDVO_CLK 

SDVO_CLK 

  

  

D74 

 

SD 

TMDS 

DPC_LANE3 

D75 

PEG_TX7- 

SDVOC_CLK- 

TMDS_2_CLK - 

DPC_LANE3# 

D76 

GND 

  

GND 

GND 

D77 

IDE_CBLID# 

  

IDE_CBLID# 

IDE_CBLID# 

D78 

 

  

DVO_SDA 

DPD_LANE0 

D79 

PEG_TX8- 

  

DVO_SCL 

DPD_LANE0# 

D80 

GND (FIXED) 

  

GND (FIXED) 

GND (FIXED) 

D81 

 

  

DVO_HPD 

DPD_LANE1 

D82 

PEG_TX9- 

  

  

DPD_LANE1# 

D83 

RSVD 

  

RSVD 

RSVD 

D84 

GND 

  

GND 

GND 

D85 

  

  

DPD_LANE2 

D86 

PEG_TX10- 

  

  

DPD_LANE2# 

D87 

GND 

  

GND 

GND 

D88 

  

DVO CLK- 

DPD_LANE3 

D89 

PEG_TX11- 

  

  

DPD_LANE3# 

D90 

GND (FIXED) 

  

GND (FIXED) 

GND (FIXED) 

D91 

  

  

  

D92 

PEG_TX12- 

  

  

  

D93 

GND 

  

GND 

GND 

D94 

  

  

  

D95 

PEG_TX13- 

  

  

  

D96 

GND 

  

GND 

GND 

D97 

PEG_ENABLE# 

  

PEG_ENABLE# 

PEG_ENABLE# 

D98 

  

  

  

D99 

PEG_TX14- 

  

  

  

D100 

GND (FIXED) 

  

GND (FIXED) 

GND (FIXED) 

D101 

  

  

  

D102 

PEG_TX15- 

  

  

  

D103 

GND 

  

GND 

GND 

D104 

VCC_12V 

  

VCC_12V 

VCC_12V 

D105 

VCC_12V 

  

VCC_12V 

VCC_12V 

D106 

VCC_12V 

  

VCC_12V 

VCC_12V 

D107 

VCC_12V 

  

VCC_12V 

VCC_12V 

D108 

VCC_12V 

  

VCC_12V 

VCC_12V 

D109 

VCC_12V 

  

VCC_12V 

VCC_12V 

D110 

GND (FIXED) 

  

GND (FIXED) 

GND (FIXED) 

Summary of Contents for COM Express Extension

Page 1: ...COM Express Extension Specification Rev 013...

Page 2: ...This page intentionally left blank...

Page 3: ...COM Express Type 1 10 Figure 3 Small Form Factor nano 11 4 Signal Description 12 4 1 Graphic Signal Description 12 4 1 1 Table Graphic Signal Description Row C for Pin out Type 2 12 4 1 2 Table Graph...

Page 4: ...for default settings 20 7 Apendix A PC Architecture Information 21 7 1 Buses 21 7 1 1 ISA Standard PS 2 Connectors 21 7 1 2 PCI21 7 2 General PC Architecture 21 7 3 Ports 22 7 3 1 RS 232 Serial 22 7...

Page 5: ...rd and administrates the COM Industrial Group s website http www com ig org All rights reserved No part of this document may be reproduced transmitted transcribed stored in a retrieval system or trans...

Page 6: ...comexpress extension com specs specs php The COM Express Design Guide explores the requirements of the COM Express Extension Specification and provides recommendations on designing COM Express basebo...

Page 7: ...nts The COM Express Extension specification has been created to support to a range of vertical embedded markets It has been formulated to be applicable to a broad range of system types from floor inst...

Page 8: ...de choice of modules providing a scalable range of price and performance upgrade options 2 4 Objective Consistent with the objective of the PICMG COM Express Specification the COM Express Extension sp...

Page 9: ...ility allows that a carrier board designed to accommodate an extended module can also support a basic module microETXexpress or nanoETXexpress modules This holds true for any future defined compact mo...

Page 10: ...le sizes Copyright COM Express Extension Specification Rev 013 10 Figure Overview three module sizes All coordinates in mm top view X1 is on bottom side seen through pcb 3 1 1 Small Form Factor nano C...

Page 11: ...gure Small Form Factor nano All dimensions are shown in millimetres Tolerances should be 0 25mm 0 010 unless noted otherwise The tolerances on the module connector locating peg holes dimensions 16 50...

Page 12: ...interface 4 1 1 Table Graphic Signal Description Row C for Pin out Type 2 Row C Definition PCIE x 16 SDVO TMDS DVI HDMI DVO Display Port Pin No Pin Name C52 PEG_RX0 SDVO_TVCLK HDMI_TVCLKIN C53 PEG_RX...

Page 13: ...EG_RX15 DVO HS C102 PEG_RX15 DVO VS C103 GND GND GND C104 VCC_12V VCC_12V VCC_12V C105 VCC_12V VCC_12V VCC_12V C106 VCC_12V VCC_12V VCC_12V C107 VCC_12V VCC_12V VCC_12V C108 VCC_12V VCC_12V VCC_12V C1...

Page 14: ...2_CLK DPC_LANE3 D76 GND GND GND D77 IDE_CBLID IDE_CBLID IDE_CBLID D78 PEG_TX8 DVO_SDA DPD_LANE0 D79 PEG_TX8 DVO_SCL DPD_LANE0 D80 GND FIXED GND FIXED GND FIXED D81 PEG_TX9 DVO_HPD DPD_LANE1 D82 PEG_TX...

Page 15: ...d if the standby functions are not required by the application Likewise the 3V battery input may be left open if the application does not require the RTC to keep time in the absence of the main and st...

Page 16: ...ious COM Express compliant modules and carrier boards Pin Description Recomended Use Function Comment GPI0 General Purpose Input LID Button Power Management Event Please see Board Specification GPI1 G...

Page 17: ...r data bus widths can be configured for data transfer SD_CMD I O CMOS3 3 SDIO Controller 0 1 2 Command This signal is used for card initialization and transfer of commands It has two operating modes o...

Page 18: ...ontrol the fan depending on the Active Trip Point temperature The fan switches on off depending on the adjusted Active Trip Point temperature In order for this feature to function properly an ACPI com...

Page 19: ...ic TPM features more information TBD COM Express Extension COMs are compliant to TCG 1 2 That includes efficient processing of hash and RSA algorithms with key length up to 2048bit and random generato...

Page 20: ...there still often is the need for legacy interfaces like serial port parallel port floppy etc To make an adaption of these ports possible the BIOS of COM Express modules has integrated support for LP...

Page 21: ...d P996 Draft D2 00 Jan 18 1990 IEEE Inc Technical Reference Guide Extended Industry Standard Architecture Expansion Bus Compaq 1989 7 1 2 PCI PCI SIG The PCI SIG provides a forum for its 900 member co...

Page 22: ...conductor The Interface Data Book includes application notes Type 232 as search criteria to obtain a list of application notes You can search for information about the data book on National Semiconduc...

Page 23: ...S 1987 ISBN 0 672 22584 0 Programmer s Guide to the EGA VGA and Super VGA Cards Third Edition Richard Ferraro Addison Wesley 1990 ISBN 0 201 57025 4 The Programmer s PC Sourcebook Second Edition Thom...

Page 24: ...Su Neutral document format Update by comments of Aaron Su 0 5 15 05 07 Z Loncaric P M ller Brand COM Express Extension Updates for chapters 4 1 Grafic signal description 5 2 General GPIOs 5 3 Thermal...

Reviews: