![Kontron COM Express Eval 10 User Manual Download Page 11](http://html1.mh-extra.com/html/kontron/com-express-eval-10/com-express-eval-10_user-manual_1996251011.webp)
COM Express® Eval Type 10
/ Specification
8
3.4
Electrical Specification
Supply Voltage
»
ATX Main Power 24pin
»
ATX_12V P4 connector (wide range input depends on module specification)
Power Supply Rise time
»
The input voltages shall rise from ≤10% of nominal to within the regulation ranges within 0.1ms to 20ms.
»
There must be a smooth and continuous ramp of each DC input voltage from 10% to 90% of its final set-point
following the ATX specification
Supply Voltage Ripple
»
Maximum 100 mV peak to peak 0-20MHz