Kontron 820152 User Manual Download Page 4

 

820152 DC-DC Supply 12Vin 120W 

 KTD-00695-D 

Public  User Manual 

Date: 2009-11-03  Page

4 of 4 

 

 

Specifications

 

 
 

Input Requirements

 

 
12V regulated, +5% / -3%, max=10A (load dependent). Over-voltage shutdown will occur at ~13-13.5V. 
 
DC-Jack: Female, panel mount, 2.5 * 5.5 * 10 mm. 
 
 

Voltage outputs 

 

Output 

voltage 

Max Load / [A] 

(Fan less) 

Max Load / [A] 

(Forced air) 

Peak Load / 

[A] 

(<60 sec.) 

Regulation 

5V 4,8  6 

+/- 

1.5% 

5VSB 1,5  1.5 

+/- 

1.5% 

3.3V 4,8 

+/- 

1.5% 

-12V 0,05  0.05  0.1 

+/- 

5% 

12V 6  6  10 

Switched 

input 

 
Over load protection will be effected when either of the loads (+5V & +3.3V) exceeds > 200% Max Load. 
 
After turning on, at least 20 ms will be needed for the rise of +5VSB output voltage (measured from 10% to 
95%) to reach its peak. 
 
 

Efficiency Ratings, 3.3 and 5V 

 

5V / [A]  Efficiency / [%]

3.3V / [A]

Efficiency / [%] 

1 86  1  85 
3 94  3  93 
5 96  5  94 
8 93  8  91 

 
 

Lifetime

: MTBF=100K hours at 55 ºC. 

 
 

Size

: (L, W, H) = (44.5, 20, 30) mm 

 
 

Operating environment

: Temperature: -20 to 85 ºC. Relative Humidity 10 to 90% (non-condensing). 

 
 

Shipping and storage

: Temperature -40 to +90 ºC. Relative humidity 5 to 95% (non-condensing). 

 
 

Certifications

: EN55024, EN55022 Class B (CE certification), Australia/New Zealand (using CISPR 22, 

EN55022), Japan (VCCI: using CISPR 22, ANSI C63.4), United States (FCC Part 15, Subpart B, Class B), 
Canada (ICES-003 using CISPR 22, ANSI C63.4) 
 
 
 

Reviews: