KSwitch D10 MMT Managed Time Sensitive Ethernet Switch - Preliminary User Guide, Rev. 0.99
// 39
To install the switch on a DIN-Rail, perform the following:
1.
Fasten the DIN-Rail clip on the switch in the upper position (Figure 10) using the three screws (M3x5) provided
with the DIN-Rail clip.
2.
Hook the top of the DIN-Rail clips over the DIN-Rail and push down slightly while moving the bottom of the
switch towards the DIN-Rail until the DIN-Rail clip snaps into place.
3.
Check the switch is securely attached to the DIN-Rail.
6.2.
DIN-Rail Removal
To remove the switch from a DIN-Rail, perform the following:
1.
Push the switch down to free the bottom of the DIN-Rail clip from the DIN-Rail.
2.
Rotate the bottom of the switch away from the DIN-Rail.
3.
Unhook the top of the DIN-Rail clip from the DIN-Rail by lifting upwards.
4.
Remove the DIN-Rail clip by loosening and removing the three screws (M3x5). Retain the three screws with the
removed DIN-Rail clip.
6.3.
Wall Mounting
To mount on a flat surface or wall use the Wall Mount Kit containing two wall mount plates and four (M3x5) screws
to mount the wall mount plate to the switch, see Table 2: Mounting Kit Accessories.
Table 7: Mounting with Wall Mount Plates
1
2 threaded screws hole
2
Grove to mount with screw on a wall or
flat surface
Secure Switch Properly
Secure the wall mount plates using all four screws (M3x5) provided and mount on a wall or
flat surface using two screws that match the mounting surfaces length requirements.
27 mm (1.06 inch)
2
1