KSwitch D10 MMT Managed Time Sensitive Ethernet Switch - Preliminary User Guide, Rev. 0.99
// 38
6/
Mounting
Before installing or removing the switch read and observe the instructions within this user guide, including
Chapter 2/: General Safety Instructions. Kontron assumes no responsibility for any damage resulting from failure to
comply with these requirements.
Install the switch in the power off state only.
Before installing the switch consider the required orientation of the switch within the
installation environment and access to connectors
The switch is fanless and passively cooled by a heatsink positioned on the left side of the switch. When installing the
switch consider the ambient temperature in the installation environment around the switch. To allow for adequate
heat dissipation without obstructions ensure a clearance of at least 20 mm around the switch.
Prevent Overheating
Mount leaving a clearance of at least 20 mm around the switch, to ensure proper operation
and prevent the switch from overheating.
6.1.
DIN-Rail Mounting
The DIN-Rail clip enables easy installation or removal of the switch.
Figure 10: DIN-Rail Clip Upper Position