1.

 Short circuit protection.

 The charger will automatically power off if the terminals 

are short-circuited.
2. 

Overtemperature protection.

 The charger powers off in two situations, as de

-

scribed below, and automatically enters the charging mode when the operating tem-

perature is restored:
a). When the charger has been exposed to high temperatures for a long time;
b). When the temperature inside the charger exceeds the operating temperature.
3. 

Spark protection.

 The terminals are not energized until the battery is connected.

Use the correct charging voltage according to 

the battery’s rated voltage! Do not charge the 

battery when the engine is running!

WARNING!

3

SAFETY FUNCTIONS

1. Power indicator

1. Power indicator
2. Fault indicator

2. Fault indicator
3. Mode selection button

3. Mode selection button
4. 6 V indicator

4. 6 V indicator
5. 

5. 12 V 

12 V indicator

indicator

1

1

5

5

2

2

3

3

4

4

2.Press the MODE button to select the appropriate charging voltage that matches the 

battery’s rated voltage: select 6 V charging voltage for a 6 V battery and 12 V charging 

voltage for a 12 V battery. The selected mode will turn green.
3.The charger will automatically enter the charging mode. If the voltage at the battery 

terminals is more than 2 V, the power indicator will flash green. If the voltage is less than 

2 V, the charging process will not start.
4.When the battery is fully charged, the charger will automatically enter trickle charge 

mode and the power indicator will light up green.
5.Before disconnecting the battery, unplug the charger from the mains supply and then 

remove the terminals from the battery.
6.If the battery is faulty, the fault indicator will go on.

Summary of Contents for KS B1A

Page 1: ...Automatic Battery Charger Please read this manual carefully before use Owner s Manual KS B1A EN ...

Page 2: ...er de en This automatic battery charger is intended for charging 6 V 12 V lead acid batteries It is used to charge batteries of generators cultivators motorcycles snowmobiles boats four wheelers etc with a capacity of up to 32 A h After selecting the required voltage the charging process is carried out automatically 1 Getting started Connect the red terminal to the side of the battery and the blac...

Page 3: ... indicator 2 Fault indicator 3 Mode selection button 3 Mode selection button 4 6 V indicator 4 6 V indicator 5 5 12 V 12 V indicator indicator 1 1 5 5 2 2 3 3 4 4 2 Press the MODE button to select the appropriate charging voltage that matches the battery s rated voltage select 6 V charging voltage for a 6 V battery and 12 V charging voltage for a 12 V battery The selected mode will turn green 3 Th...

Page 4: ... for inspection 2 Power indicator is on but the charging process does not start 1 Check connection of the terminals to the battery 2 Check the terminals for sulfiding 3 Check the terminal wire for damage If it is damaged do not try to replace it yourself Return the charger to the service center 4 The charger has activated overtemperature protection Wait a while for the charger to cool down 5 Wrong...

Page 5: ...turer warranty is 1 year The warranty period starts from the date of purchase In cases where a warranty period is longer than 1 year according to local legislation please contact your local dealer The Seller of the product is responsible for granting the warranty Please contact the Seller for warranty If the product fails within the warranty period because of defects in workmanship it will be exch...

Page 6: ...und Unterstützung und Unterstützung support dimaxgroup de Garantie Reparatur und Service Garantie Reparatur und Service service dimaxgroup de Sonstiges Sonstiges info dimaxgroup de Polska Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de Україна Україна ТОВ Техно Трейд КС вул Електротехнічна 47 02222 м Київ Україна www ks pow...

Reviews: