background image

1. Hardware Description

1.1. Specifications

Classification

Parameter

Specification

AC Input

AC Channels

6

Connector

Terminal block

AC Type

Wet contact

Channel-to-Channel Isolation

1500Vrms

Acquisition Frequency

1kHz

Logic

Logic 0: ≤ 75VAC, Logic 1: 90~275VAC

Upstream Serial Port

Serial Standrad

RS485

No. of Ports

1

Connector

Terminal block

Serial Protocol

Modbus RTU

Power

Power Connector

Terminal block

Input Voltage

9~27VDC

Current

30mA @ 12VDC

Power

≤ 0.3W

Physical Characteristics

Dimensions

75*105*30mm

Installation

Din-rail or wall

Environmental Limits

Operating Temperature

-40℃ ~ 85℃

Storage Temperature

-60℃ ~ 125℃

Ambient Relative Humidity

5% ~ 95% RH, non-condensing

C2000-A2-SDX6000-CX1 User Manual

5 / 11

SinoCon Co., Ltd. 

www.sinoconsys.com

Summary of Contents for C2000-A2-SDX6000-CX1

Page 1: ...Last updated 2019 12 13 C2000 A2 SDX6000 CX1 User Manual RS485 6AC AC 90 275V Remote I O Module AC Digital Input Module SinoCon Co Ltd ...

Page 2: ...dware Description 1 1 Specifications 1 2 Apprearance 1 3 Indicators 1 4 Port Description 1 5 Product Dimensions 1 6 Installation Method 2 Package Contents 3 Warranty Policy C2000 A2 SDX6000 CX1 User Manual 2 11 SinoCon Co Ltd www sinoconsys com ...

Page 3: ... liability stated by SinoCon in the terms and conditions of sale of its products and SinoCon makes no warranties regarding the sale or use of KonNaD products including the suitability for the specific use of the products and marketability and SinoCon doesn t guarantee that it won t infringe any patent copyright or other intellectual property rights etc Information in this document is subject to ch...

Page 4: ...C2000 A2 SDX6000 CX1 User Manual 4 11 SinoCon Co Ltd www sinoconsys com ...

Page 5: ...Serial Port Serial Standrad RS485 No of Ports 1 Connector Terminal block Serial Protocol Modbus RTU Power Power Connector Terminal block Input Voltage 9 27VDC Current 30mA 12VDC Power 0 3W Physical Characteristics Dimensions 75 105 30mm Installation Din rail or wall Environmental Limits Operating Temperature 40 85 Storage Temperature 60 125 Ambient Relative Humidity 5 95 RH non condensing C2000 A2...

Page 6: ...1 2 Apprearance C2000 A2 SDX6000 CX1 User Manual 6 11 SinoCon Co Ltd www sinoconsys com ...

Page 7: ...ive poles of 485 line are reversed Flashing RS485 receiving data Off RS485 no receiving data TXD RS485 data transmit indicator Flashing RS485 transmitting data Off RS485 no transmitting data Power PWR Power indicator Steady on Normal power supply Off No power or abnormal power supply please check if the voltage range is 9 27VDC RUN RUN Running indicator Steady on Device exception Flashing Flashes ...

Page 8: ...re AC neutral wire Upstream Serial Port RS485 RS485 upstream RVSP 2 0 5 Power Input V V Power supply input positive power supply input negative RVV 2 1 0 PE Used for reliable grounding of the device surge protection RVV 2 0 5 C2000 A2 SDX6000 CX1 User Manual 8 11 SinoCon Co Ltd www sinoconsys com ...

Page 9: ...1 5 Product Dimensions unit mm inch 1 6 Installation Method C2000 A2 SDX6000 CX1 User Manual 9 11 SinoCon Co Ltd www sinoconsys com ...

Page 10: ...2 Package Contents No Contents 1 Device contain mounting kit 1 2 Terminal block 1 set 3 Installation guide card 1 C2000 A2 SDX6000 CX1 User Manual 10 11 SinoCon Co Ltd www sinoconsys com ...

Page 11: ...y period or that have been improperly installed incorrectly input voltage improperly used accidental events or natural disasters etc are not covered by the warranty 3 Before accepting the warranty service the customer is required to prove the date of purchase of the product by presenting the warranty card or purchasing the invoice Otherwise the warranty cannot be guaranteed 4 For all warranty or r...

Reviews: