Konlen KL-H50 User Manual Download Page 19

 

KONLEN TECHNOLOGY LIMITED 

Website: www.konlen.com

 

U1 building, Oriental Garden, NanShan District, Shenzhen City, Guangdong Province,China 

Tel: +86-(0)755-86082432 E-mail: 

[email protected]

 MSN: 

[email protected]

 Skype: securitykonlen 

 

- 19 - 

18                              wireless zone 24 alarm 

19                              wireless zone 25 alarm 

1A                              wireless zone 26 alarm 

1B                              wireless zone 27 alarm 

1C                              wireless zone 28 alarm 

1D                              wireless zone 29 alarm 

1E                              wireless zone 30 alarm 

1F                              wireless zone 31 alarm 

20                              wireless zone 32 alarm 

21                              fire zone 01 alarm 

22                              fire zone 02 alarm 

23                              fire zone 03 alarm 

24                              fire zone 04 alarm 

25                              emergency zone 01 alarm   

26                              emergency zone 02 alarm   

27                              emergency zone 03 alarm   

28                              emergency zone 04 alarm   

29                              wired door/window zone 01 alarm 

2A                              wired door/window zone 02 alarm 

2B                              wired zone 03 alarm 

2C                              wired zone 04 alarm 

2D                              wired zone 05 alarm 

2E                              wired zone 06 alarm 

2F                              wired zone 07 alarm 

30                              wired zone 08 alarm 

31                              tamper switch alarm 

 

 

8. Operation Cautions 

1.  The equipments are not water-proof, not suitable for outdoor use. 

2.  Install the system in a hidden place. 

3.  Turn off the power supply before insert/take out the SIM card. 

4.  Connect the power supply firmly and provide good heat dissipation. 

5.  Don’t install the system close to the objects which generate strong magnetic interference, such as 

TV      set and computer. 

6.  Check all the detectors and their battery in time and change them when voltage is low. 

7.  Check the GSM alarm system regularly.   

 
 

 

 

Summary of Contents for KL-H50

Page 1: ...U1 building Oriental Garden NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 1 KL H50 GSM HOME A...

Page 2: ...rs for call alarm 3 2 4 Set delete check 1 SMS forwarding phone number 3 2 5 Recording voice 3 2 6 Change passwords 3 2 7 Change ID 3 2 8 Set date time 3 2 9 Set cancel fixed time arm disarm 3 3 Learn...

Page 3: ...The function in details as follows 1 1 Function Feature Color LCD screen keypad with blue background light Maximum 4 wireless panic buttons 4 wireless fire detectors 16 remote controllers 32 wireless...

Page 4: ...Hz DC9V Backup battery Li DC7 4V 700MAH Operating temperature 20 60 Humidity 95 Accessories PARAMETER Wireless frequency 315 0 2Mhz 433 0 2Mhz Coding type Learning code Power requirements Remote contr...

Page 5: ...QTY IMAGE Remark Main unit 1pcs Remote controller 2pcs Arm disarm main unit Indoor wired siren 1pcs Wireless door window contact 1pcs With low voltage reminder function Wireless PIR sensor 1pcs With l...

Page 6: ...den NanShan District Shenzhen City Guangdong Province China Tel 86 0 755 86082432 E mail klalarm konlen com MSN konlensales hotmail com Skype securitykonlen 6 1 4Main unit layout Note The background b...

Page 7: ...ow contact sensor The door window magnetic contact includes two parts The sensor will send the wireless signal to the main unit immediately when the two parts depart more than 15 30mm 2 2 2 Install PI...

Page 8: ...than air installation height from floor 0 3m 1 0m semi diameter to gas sources 1 5m detecting the gas lighter than air installation height from ceiling 0 3m 1 0m semi diameter to gas sources 1 5m 2 2...

Page 9: ...one numbers for SMS alarm a Set the mobile phone number After passing the verification of administrator password press SET button when SET SMS appears on the LCD display input N mobile phone number OK...

Page 10: ...on of administrator password press SET button to move cursor when SET REC appear on the LCD display press OK to begin the 9 seconds record The main unit LCD starts to count down and exits automaticall...

Page 11: ...rn cancel remote controller a Learn remote control After passing the verification of administrator password press SET button to move cursor when SET COM appears on the LCD display input 1 N OK the LCD...

Page 12: ...OK on Main unit keyboard the LCD will stop to flash in 4s All of them are deleted 3 4 Exit setting In the setting mode press ESC to exit The setting mode will exit automatically if no response within...

Page 13: ...numbers for SMS alarm a Set the mobile phone number SMS format four digits of administrator password DS N mobile phone number Note N stands for 1 2 3 4 5 Example Set 1388888888 as the first SMS receiv...

Page 14: ...8 as the new password Send SMS 1234DP5678 5 5 Arm disarm Arm by SMS 4 digits of administrator password A1 Disarm by SMS 4 digits of administrator password A2 Example The Main unit s administrator pass...

Page 15: ...5s Note Zone 1 and zone 2 can be set as delay alarm zones Suggest users to install the delay alarm zone sensors on the way from door to alarm main unit User will have enough time to disarm the alarm s...

Page 16: ...and the LCD show LO zone number to remind of users change battery 6 5 Deal with alarm SMS TEL and zones appear on the LCD display in alarm mode P external power failure E Emergency alarm F fire alarm...

Page 17: ...unication If the user hand up the phone the host will automatically terminate the operation 7 Events record History record a After passing the verification of administrator password press SET button t...

Page 18: ...disarm by 8th remote controller A8 disarm by 9th remote controller A9 disarm by 10th remote controller AA disarm by 11th remote controller AB disarm by 12th remote controller AC disarm by 13th remote...

Page 19: ...02 alarm 27 emergency zone 03 alarm 28 emergency zone 04 alarm 29 wired door window zone 01 alarm 2A wired door window zone 02 alarm 2B wired zone 03 alarm 2C wired zone 04 alarm 2D wired zone 05 ala...