STATUS light will be red for 20 seconds. During this time make sensors to work (press any
button on remote controller, make PIR and gap sensors (move the two parts of door sensor) to
work). They will be recognized and coded in the system. After 20s system is ready to work
when the Status light turns green.
Test all sensors and repeat procedure for any sensor, if is necessary.
Maximum number of wireless sensors that can be coded by system is 10. But you can register
countless wireless sensors by changing sensors’ ID.
3.
Connecting wired sensors
Three inputs are available to connect wired sensors. Inputs are independent, but are not coded as
different zones. When sent SMS, it will show Wired Activated
Sensors must be NC (normally closed) type.
You can connect more than 1 sensor at one input, connecting their alarm contacts serial.
Can be used any number of wired sensors, as long as total resistance is under 220 ohms.
4.
Connecting switched output devices
Three open collector outputs and one internal relay controlled by telephone are available.
Internal onboard relay is activated when an alarm occurs and can be deactivated/reactivated thru
telephone commands.
It can be used, as example, to command an external lamp.