Installation
Inspection
Inspect the UPS upon receipt. The packaging is recyclable. Save it for re-use or dispose of it
properly.
Placement
Install the UPS in a protected area with adequate airfl ow, and away from direct sunlight and excessive
dust. Do not operate the UPS where the temperature and humidity are outside the specifi ed limits in
the Specifi cations Table.
Connect to Utility
Connect the AC input power connector to utility power to power up the UPS.
Charge the battery
The battery in the UPS will lose some charge in shipping and storage. It will recharge completely
after approximately 8 hours of normal operation. Do not expect full battery runtime during this initial
recharge period.
Connect the loads
Plug the loads into the output connectors on the rear of the UPS.
Caution:
Never connect a laser printer or plotter to the UPS with other computer equipment. A laser
printer or plotter periodically draws signifi cantly more power than when idle, and may overload the
UPS.
Operation
Switch On
With the UPS plugged in, press and hold the POWER button more than 4 seconds until a beep
sounds to switch the UPS on. The UPS will perform self-testing each time when it is switched on.
Switch Off
By pressing and hold the POWER button more than 4 seconds until hearing one beep sound.
Self-Test
In normal utility power, push the POWER button less than 1 second and UPS performs a self-test
on the battery capacity. During the self-test, the UPS operates a backup mode, the BATTERY and
FAULT icon stay on.
Backup (slow alarm)
When in Backup mode, the BATTERY and FAULT icon illuminates and the UPS emit a beep every
four seconds. The alarms stops when the UPS returns to the utility power operation. Press the
POWER button to stop the beep.
Low Battery (rapid alarm)
In Backup mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down
from battery exhaustion or return to utility power operation.
Overload (continuous alarm)
When the UPS is overloaded, the OVERLOAD icon illuminates and the UPS emits continuous alarm
for 30 seconds to warn for an overload status. Disconnect nonessential load equipment from UPS to
eliminate the overload.
Summary of Contents for CMP-UPS500
Page 1: ...CMP UPS500 650 800C UPS 500 650 800VA Charger ...
Page 3: ...Front Rear 2 ...
Page 8: ...7 ...
Page 9: ...CMP UPS500 650 800C USV 500 650 800VA Ladegerät ...
Page 11: ...2 Vorderseite Rückseite ...
Page 16: ...7 ...
Page 17: ...CMP UPS500 650 800C Onduleur 500 650 800VA Chargeur ...
Page 19: ...2 Vue avant Vue arrière ...
Page 24: ...7 ...
Page 25: ...CMP UPS500 650 800C UPS 500 650 800VA Oplader ...
Page 27: ...2 Voorkant Achterkant ...
Page 32: ...7 ...
Page 33: ...CMP UPS500 650 800C UPS 500 650 800VA Caricatore ...
Page 35: ...2 Parte anteriore Parte posteriore ...
Page 40: ...7 ...
Page 41: ...CMP UPS500 650 800C UPS 500 650 800VA Cargador ...
Page 43: ...2 Panel frontal Trasero ...
Page 48: ...7 ...
Page 49: ...CMP UPS500 650 800C UPS 500 650 800VA Töltő ...
Page 51: ...2 Elölnézet Hátulnézet ...
Page 56: ...7 ...
Page 57: ...CMP UPS500 650 800C UPS 500 650 800VA Laturi ...
Page 59: ...2 Edestä Takaa ...
Page 64: ...7 ...
Page 65: ...CMP UPS500 650 800C UPS 500 650 800VA Laddare ...
Page 67: ...2 Framsida Baksida ...
Page 72: ...7 ...
Page 73: ...CMP UPS500 650 800C UPS 500 650 800VA Nabíječka ...
Page 75: ...2 Přední strana Zadní strana ...
Page 80: ...7 ...
Page 81: ...CMP UPS500 650 800C UPS 500 650 800VA Încărcător ...
Page 83: ...2 Faţă Spate ...
Page 88: ...7 ...